Comparison of effective phacoemulsification time and corneal endothelial cell loss using three different ultrasound frequencies in phacoemulsification
试验速览
- 阶段
- Phase 3 4
- 状态
- 已完成
- 发起方
- 入组人数
- 165
- 试验地点
- 1
- 主要终点
- EFFECTIVE PHACOEMULSIFICATION TIME
研究概览
简要总结
Phacoemulsification is today the most popular surgery for cataract worldwide. The nucleus is emulsified using a machine which provides energy for emulsifying the nucleus and generates a vacuum for aspirating the cortex. The method is constantly being improved to minimize the risk of complications, particularly tearing of the capsule and dropping of the nucleus into the vitreous ,and corneal endothelial damage.1 Effective phaco time is time taken to remove cataract if continuous 100% phaco power is used. Lower the effective phaco time, lower the energy delivered in the eye and thus clearer the cornea with better visual rehabilitation.2
Phacoemulsification is ultrasound based dissolution of lens matter. The piezoelectric crystal imparts a specific frequency vibratory motion to the phaco tip which when interacts with the lens matter in a fluid based environment leads to disintegration and dissolution of the cataractous lens. It is in accordance with the principles of physics that subjecting a solid to a frequency matching its internal resonant frequency would lead to disintegration of intermolecular bonds and make it easily aspirable. Biological experiments have shown supporting evidence in other human tissue.3
Increasing hardness of cataract is associated with change in chemical and physical properties in the crystalline lens and should logically require a change in frequency of ultrasound. However different machines, though within the range of 22-60 kHz, use the same frequency ultrasound (inherent to the machine) for all grades of cataract and hence end up with higher effective phaco time in hard cataract.4
Higher effective phaco time is associated with increase in endothelial damage5and using optimal frequency should reduce effective phaco time and hence corneal endothelial loss during phaco. So far the studies have compared machines with different frequencies in cataract but unique phacodynamics of each machine brings in other confounding variables making the results questionable. In a pilot study we found lower effective phaco time with use of higher frequency ultrasound6. Based on these results an RCT was conducted after ethical approval comparing 28 and 42 kHz frequencies in the same machine Megatron S4. The result showed decrease in effective phaco time and endothelial cell loss with use of higher frequency. The present Geuder
Megatron S4 HPS phaco machine delivers ultrasound frequency range from 27-55 kHz. We wish to conduct a randomized controlled trial comparing three frequencies 28kHz, 42kHz, and 55kHz in the same machine in patients with identical parameters and see if we arrive at statistically significant results through the comparison.
RESEARCH QUESTION
Is there any difference in effective phaco time and endothelial cell loss between three different ultrasound frequencies in phacoemulsification?
HYPOTHESIS
There is difference in effective phaco time and endothelial cell loss between three different ultrasound frequencies in patients of cataract undergoing phacoemulsification
研究设计
- 研究类型
- Interventional
- 分配方式
- Coin toss, Lottery, toss of dice, shuffling cards etc
- 盲法
- Participant and Outcome Assessor Blinded
入排标准
- 年龄范围
- 40.00 Year(s) 至 99.00 Year(s)(—)
- 性别
- All
入选标准
- •1.Patients of age >40 yrs having Grade 4.0-6.9 (LOCS III grading) of senile cataract 2.Patients willing to participate in the study with written consent.
排除标准
- •1.Patients with pre-operative endothelial cell density count less than 1500 cells/mm2 .
- •2.Eyes with any kind of corneal dystrophy or corneal scars preventing visualisation of cataract for reliable grading 3.Raised intraocular pressure (> 21 mmHg) 4.Previous intraocular surgery.
结局指标
主要结局
EFFECTIVE PHACOEMULSIFICATION TIME
时间窗: Peroperative
次要结局
- TOTAL ULTRASOUND TIME
- Coefficient of variation of cell size(CV)(Preoperatively,1 week, 1 month,3 months, 6 months ,9 months, 1 year)
- Best Corrected Visual Acuity(Preoperatively,1 week, 1 month)
- Endothelial Cell Density(CD)(Preoperatively,1 week, 1 month,3 months, 6 months ,9 months, 1 year)
- Intraocular Pressure(Preoperatively,1 week, 1 month)
- Central Corneal Thickness(CCT)(Preoperatively,1 week, 1 month,3 months, 6 months ,9 months, 1 year)
- Hexagonal Cell Count(6A)(Preoperatively,1 week, 1 month,3 months, 6 months ,9 months, 1 year)
