The goal of this observational study is to learn about the long-term effects of mechanical versus biological mitral valve replacement in patients aged 70 years or younger. The main question it aims to answer is:
Do patients who receive a mechanical mitral valve live longer and need fewer repeat operations compared with those who receive a biological valve? Participants are patients in Austria who already had mitral valve surgery between 2010 and 2020 as part of their regular medical care. Information about their surgeries, health conditions, and outcomes was collected from national health insurance records. Researchers will follow these patients for up to 10 years to compare survival, reoperation rates, and other heart-related events between mechanical and biological valve recipients.
- Detailed Description
This nationwide, registry-based, retrospective cohort study is part of the AUTHEART VISIT project, which investigates long-term outcomes of cardiac surgery in Austria. The present analysis focuses on patients aged 70 years or younger undergoing surgical mitral valve replacement (MVR) between January 1, 2010 and December 31, 2020. The aim is to evaluate differences in survival, reoperation rates, and cardiovascular outcomes between patients receiving mechanical mitral valve replacement (SMMVR) and those receiving biological mitral valve replacement (SBMVR).
Data source and registry procedures:
Data were obtained from the Austrian Health Insurance Funds, which cover approximately 98% of the Austrian population. The registry includes detailed patient-level information on diagnoses, procedures, and outcomes based on mandatory coding for reimbursement (ICD-10 for diagnoses and MEL codes for surgical procedures). The data are anonymized prior to analysis.
Quality assurance:
Data integrity is ensured by several mechanisms:
Data validation: Automatic data checks are performed to confirm plausibility, completeness, and consistency with predefined coding rules.
Source verification: Information is cross-checked against external records where available (e.g., insurance billing and hospital discharge data).
Data dictionary: A standardized coding framework is maintained, including MEL codes for procedures and ICD-10 for diagnoses. Definitions of outcomes are harmonized with prior AUTHEART VISIT studies.
Standard operating procedures: Established registry protocols govern data management, statistical analysis, and reporting.
Sample size and follow-up:
The study population includes all eligible patients undergoing mitral valve surgery in Austria during the study period (N=3520), with 413 undergoing sM-MVR, 487 undergoing sB-MVR, and 2620 undergoing mitral valve repair (MVRe). Median follow-up times were 6.6 years for SMMVR, 7.4 years for SBMVR, and 5.8 years for MVRe.
Handling of missing data:
Cases with implausible entries (e.g., death date before index surgery) are excluded. Missing values in baseline covariates are addressed through exclusion or handled in the propensity score weighting model. Outcome variables are based on administrative coding, minimizing missingness.
Statistical analysis plan:
The primary outcome is all-cause mortality. Secondary outcomes include reoperation, reoperation-free survival, major adverse cardiac events (MACE), myocardial infarction, heart failure, stroke, and bleeding. Time-to-event analyses are conducted using Cox proportional hazards models adjusted for age, sex, comorbidities, and concomitant procedures. To account for potential imbalances between groups, inverse probability of treatment weighting (IPTW) is applied based on a multinomial logistic regression model. Weighted and unweighted Kaplan-Meier curves are generated, with subgroup analyses by age. Cause-specific hazard models are used for secondary outcomes. Proportional hazards assumptions are evaluated using Schoenfeld residuals. A p-value \<0.05 is considered statistically significant.
This registry-based approach provides comprehensive, real-world evidence on prosthesis choice in surgical MVR, with rigorous quality assurance procedures to ensure reliability and generalizability of results.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 3520
- Mitral valve surgery between 01.01.2010 and 31.12.2020
- concomitant procedures on other valves
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Primary Outcome Measures
Name Time Method all-cause death 10 years all-cause death
- Secondary Outcome Measures
Name Time Method major adverse cardiac events 10 years major adverse cardiac events
reoperation-free survival 10 years reoperation-free survival
reoperation 10 years reoperation
myocardial infarction 10 years myocardial infarction
heart failure 10 years heart failure
stroke 10 years stroke
intracerebral hemorrhage 10 years intracerebral hemorrhage
bleeding other than ICH 10 years bleeding other than ICH