Direct Measurement of Ideal Depth of Central Line
- Conditions
- Patient Safety During Central Venous Catheterization
- Interventions
- Procedure: central venous catheterization through Rt. IJV
- Registration Number
- NCT03116724
- Lead Sponsor
- Keimyung University Dongsan Medical Center
- Brief Summary
Total of 89 patients undergoing elective cardiac surgery will be enrolled.
Right CVC insertion begins at their intersection of the cricoid cartilage level and the triangular point where the sternal head of the SCM muscle meets the clavicular head. After insertion the central venous catheter through the right internal jugular vein and positioning it, the location of the tip of the central venous catheter will be confirmed by TEE.
- Detailed Description
Investigator confirms the location of the 2 cm from the junction between right atrium and superior vena cava to the end of the tip of the catheter using TEE, and measures the insertion depth of the catheter at insertion point. It is possible to find the ideal central venous catheter insertion depth in actual clinical practice in adult patient.
The ideal central venous catheter insertion depth can be measured accurately when the end of the central venous catheter is monitored with transesophageal ultrasonography, and it can be derived a meaningful formula for predicting the ideal central venous insertion depth from the patient's height .
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 89
- adult patient over 18 years of age undergoing cardiac surgery under general anesthesia, requiring central venous catheter insertion through the right internal jugular vein and insertion of a TEE probe
- Patients who disagree with the study.
- Patients who had difficulty in inserting the central line through the right internal jugular vein.
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Arm && Interventions
Group Intervention Description CVC catheterization through Rt. IJV central venous catheterization through Rt. IJV The depth of central venous catheter during central venous catheterization through Rt. IJV will be decided by using real-time TEE. The position of tip of CVC will be guided by TEE to fit the tip at 2 cm away from the junction between right atrium and superior vena cava.
- Primary Outcome Measures
Name Time Method depth of the central venous catheter in right internal jugular vein at time of insertion of the central venous catheter
- Secondary Outcome Measures
Name Time Method
Trial Locations
- Locations (1)
Dongsan medical center