Brief Summary

The aim of this research protocol is to undertake evaluation of new and emerging MR techniques in patients and healthy volunteers following software or hardware upgrades, as well as for newly developed MR techniques; to establish their feasibility, image quality and/or measurement repeatability/ reproducibility.

Detailed Description

This study is a 'master protocol', analogous to an umbrella trial design, that seeks to evaluate multiple new MR techniques. As such, the study is designed to identify promising techniques that merit further investigation. Following successful evaluation as part of this study, new MR techniques will either be adopted into clinical practice or developed further in a larger research study.

Type 1) The new measurements are added to an existing patient examination, to allow evaluation of the benefits of the new approach in comparison with standard procedures, in the pathology of interest. This frequently is required during development of a new approach, when measurements indicate shortcomings that can be corrected by modification of the sequence, or in assessing a new software release from the manufacturer, which provides a range of new or improved facilities, that must be assessed in relation to our established approach. In this case patients undergoing established procedures or protocols will be measured with additional sequences provided that the additional examinations do not add more than 15 minutes to the total examination, that exposure is below or within the first level controlled MR safety mode, and is not indicated to be likely to cause any adverse effects. No additional intra-venous contrast agents will be administered (patients will receive intra-venous contrast agent if indicated as part of their routine examination). These measurements will be performed with verbal consent from the patient, which will be documented in the patient's Electronic Patient Record (EPR).

Type 2) The measurements for evaluation or development of a new technique (usually in a research setting) require a complete measurement or series of measurements to evaluate the technique in appropriate pathology, often during the course of treatment. These measurements will typically last for 30-60 minutes, the duration of standard MR examinations. In exceptional circumstances these measurements will last up to 90 minutes. Measurements will be conducted with the consent of the clinician responsible for the patient, which will be documented in the patient's Electronic Patient Record (EPR). Measurements will be performed with written informed consent from the patient. As this is a dedicated session for the purpose of evaluating the new technique, this will require informed consent with a clear indication of any potential adverse effects in the patient information sheet, even if such measurement is performed during a routine clinically indicated or research examination. No intra-venous contrast agents will be administered as a part of this protocol.

Type 3) The measurements for evaluation or development of a new technique require measurements in normal volunteers to establish the correct operation and value of the technique, and in some cases to assess measurement repeatability or reproducibility. These measurements will typically last for 30-60 minutes, the duration of standard MR examinations. In exceptional circumstances these measurements will last up to 90 minutes. Measurements will be performed with written informed consent from the volunteer. Any potential adverse effects will be clearly indicated in the volunteer information sheet. No intra-venous contrast agents will be administered.

Recruitment & Eligibility

Status
RECRUITING
Sex
All
Target Recruitment
2850
Inclusion Criteria
  • Type 1: Patients undergoing a routine clinical MR examination using established MR techniques to which an additional new sequence is added for evaluation, who give verbal consent for additional data to be acquired for evaluation of a new MR technique.
  • Type 2: Patients who voluntarily agree to participate in the study by giving written informed consent.
  • Type 3: Normal volunteers who voluntarily agree to participate in the study by giving written informed consent.
Exclusion Criteria
  • Standard MR Exclusion criteria apply to all MR examinations, as documented in the MRI Local Rules.
  • Patients or volunteers who are unwilling to undergo an additional MR examination, for example due to claustrophobia, will be excluded from the study.
  • Normal volunteers who do not have an NHS number or who are not registered with a GP will be excluded.

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Primary Outcome Measures
NameTimeMethod
Qualitative assessment of a new MR technique (e.g. image quality)10 years

mage quality will be assessed using a 5-point Likert scale (1 = unacceptable/non diagnostic images, 2 = diagnostic images with some artefacts affecting interpretation, 3 = moderate quality images, 4 = good, 5 = excellent image quality with no artefacts)

Objective comparison of a new MR technique with a current MR technique10 years

(1 = unacceptable/non diagnostic images, 2 = diagnostic images with some artefacts affecting interpretation, 3 = moderate quality images, 4 = good, 5 = excellent image quality with no artefacts)

Assessment of repeatability or reproducibility of a quantitative metric using a new MR technique10 years

Repeatability or reproducibility will be assessed using two measurements separated by a short time interval using the same MRI scanner (repeatability) or a different MRI scanner (reproducibility). Bland-Altman plots will be used to assess repeatability / reproducibility and 95% limits of agreement (LoA) will be estimated.

Assessment of a new MR technique in pre- and post-treatment measurements10 years

Quantitative measurements from a new MR technique will be assessed in pre- and post treatment measurements, in order to assess the dynamic range of post-treatment changes relative to the repeatability of the measurement. These data will be used to assess whether further clinical studies are warranted for assessment of the new technique as a potential imaging biomarker. (The treatment is not part of this study, and will be standard-of-care. The timepoints will be defined relative to the standard-of-care pathway and will be fixed for all patients assessed per disease/MR technique.)

Feasibility of a new MR technique10 years

Assessment of feasibility is required at the earliest stages of development of a new MR technique. We will assess whether a new MR technique can be implemented on our MRI scanners with at least 60% success in achieving the desired measurement. 'Success' will be defined as: i. Acceptable quality of the MR image (or other MR data), assessed by a consultant radiologist or MR physicist, depending in the technique being investigated. ii. Acquisition time up to 15 minutes per sequence.

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

The Royal Marsden NHS Foundation Trust

🇬🇧

Sutton, Surrey, United Kingdom