跳至主要内容
临床试验/NCT03767088
NCT03767088已完成不适用

Evaluation of Whole-body Electromyostimulation (WB-EMS) in the Context of Inpatient Rehabilitation of Cardiological and Orthopedic Patients by Randomized Controlled Trial

Prof. Dr. Frank Mooren1 个研究点 分布在 1 个国家目标入组 134 人开始时间: 2019年1月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
134
试验地点
1
主要终点
(isometric) muscle strength of arms, legs and trunk (extenstion)

研究概览

简要总结

Based on various studies, scientific evidence has proven the effectiveness of whole-body electromyostimulation (WB-EMS) on parameters such as increased physiological performance and body composition.

As a pilot project, the aim of the study is to determine the effect of additional WB-EMS as part of the inpatient four-week rehabilitation of sarcopenic subjects.

详细描述

The loss of muscle mass in the age-associated process (sarcopenia) is a common indication in the field of orthopedic and cardiac rehabilitation, which may also be reinforced by previous immobilization and disuse of the muscles (atrophy of muscle). Sarcopenia is defined as 2 standard deviations of average of the same sex in middle adult life. The present project focuses on the sarcopenia definition of the Foundation for the National Institutes of Health (FNIH). Their limits are < 0.789 (men) and < 0.512 (women) and are calculated by adding the absolute muscle mass of the extremities divided by the body mass index (BMI).

Due to reduced muscle mass and thus limited strength / performance, the implementation of conventional training tools with regard to generate corresponding intensities is no longer possible, or in persons with additional cardiac or orthopedic restrictions heavily limited.

In view of the existing indications, the alternative training technology whole-body electromyostimulation (WB-EMS) is an adequate training tool for the rehabilitation process. The time-saving (max 20 minutes per training session) and effective training method is characterized by low orthopedic and cardiac stress. Thus, WB-EMS combines both relevant aspects of a joint-friendly training with effects on muscle mass and functionality. Through the simultaneous activation of up to 10 muscle regions with corresponding, subjectively decidedly adjustable intensity per muscle group, up to 2,800 cm2 can be addressed. Synchronized to a motion video, the participants perform light physical exercises in parallel to the current pulses.

The aim of the study is, to evaluate the effect of additional WB-EMS during a 4-week period of inpatient rehabilitation, comparing 3 groups:

  1. WB-EMS, stimulating 8 muscle groups (legs,arms, core, gluteal region)
  2. partial-WB-EMS, just stimulating the lower extremities (legs, gluteal region)
  3. control, just performing the functional, mainly eccentric motion pattern without stimulation

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

性别
All
接受健康志愿者
否

入选标准

  • •skeletal muscle index (SMI) < 0,789 (men); < 0,512 (women)
  • •A general state of good health
  • •Medically approved unrestricted sports participation as shown by diagnostic performance test
  • •Willingness to provide signed informed consent

排除标准

  • •Post-coronary artery bypass graft (ACVB) surgery in the last 3 months
  • •Condition after pacemaker and defibrillator implantation
  • •renal insufficiency from stage 3a
  • •feverish diseases or infectious diseases
  • •Taking medicines the affect muscle metabolism
  • •severe neurological disorders
  • •Skin injuries in the area of electrodes

研究组 & 干预措施

WB-EMS

Active Comparator

1.5 sessions per week; in total: 6 training sessions training duration: 20 min per session stimulation of 8 muscle groups (legs, gluteal region, core, arms) while performing slight eccentric pronounced physiological movement patterns parameters: 85 Hz, 350ms, intermittent, 4 s load vs 4 s regeneration

干预措施: WB-EMS (Device)

partial WB-EMS

Active Comparator

1.5 sessions per week; in total: 6 training sessions training duration: 20 min per session stimulation of 2 muscle groups (legs, gluteal region; lower extremities) while performing slight eccentric pronounced physiological movement patterns parameters: 85 Hz, 350ms, intermittent, 4 s load vs 4 s regeneration

干预措施: WB-EMS (Device)

control

Sham Comparator

active sham comparator: 1.5 sessions per week; in total: 6 training sessions training duration: 20 min per session performing slight eccentric pronounced physiological movement patterns

干预措施: (synchronized) Training program without WB-EMS (Other)

结局指标

主要结局

(isometric) muscle strength of arms, legs and trunk (extenstion)

时间窗: 4 weeks

isometric strength \[Nm\] (DIERs Myoline professional, DIERs International GmbH)

muscle function

时间窗: 4 weeks

chair rise test \[repetitions; n\]

muscle function / submaximal performance test

时间窗: 4 weeks

6 minute walking test \[distance; m\]

次要结局

  • blood-sample: sodium(4 weeks)
  • potassium(4 weeks)
  • muscle mass via multifrequency bioimpedance analysis(4 weeks)
  • body fat via multifrequency bioimpedance analysis(4 weeks)
  • blood-sample: triglycerides(4 weeks)
  • blood-sample: high-density lipoprotein (HDL)(4 weeks)
  • blood-sample: low-density lipoprotein (LDL)(4 weeks)
  • blood-sample: Crea/glomerular filtration rate (GfR)(4 weeks)
  • blood-sample: glutamate oxaloacetate transaminase (GOT)(4 weeks)
  • blood-sample: glutamic pyruvic transaminase (GPT)(4 weeks)
  • blood-sample: gamma-glutamyl transpeptidase (GGT)(4 weeks)
  • blood-sample: creatine kinase (CK)(4 weeks)
  • blood-sample: myoglobin(4 weeks)
  • life quality(4 weeks)
  • self-efficacy(4 weeks)
  • activities of daily living(4 weeks)

研究者

发起方
Prof. Dr. Frank Mooren
申办方类型
Other
责任方
Sponsor Investigator
主要研究者

Prof. Dr. Frank Mooren

Prof. Dr. med. (Lehrstuhl für Rehabilitationswissenschaften)

University of Witten/Herdecke

研究点 (1)

Loading locations...

相似试验