Covered Endovascular Reconstruction of Aortic Bifurcation (CERAB) for Extensive Aortoiliac Occlusive Disease
- Conditions
- Aortoiliac ObstructionAorto-Iliac Atherosclerosis
- Registration Number
- NCT03767686
- Lead Sponsor
- Rijnstate Hospital
- Brief Summary
Endovascular treatment is rapidly taking over surgery for aorto-iliac occlusive disease (AOID), also in extensive pathology. This is related to its minimally invasiveness, decreasing the procedural morbidity rate. When the aortic bifurcation was involved in the lesion, the patency rates of kissing stents configurations were often inferior to open repair. In 2013 the Covered Endovascular Reconstruction of the Aortic Bifurcation (CERAB) technique was introduced in an attempt to improve endovascular treatment results by a more anatomical and physiological reconstruction, with a subsequent improved clinical outcome.
This investigator-initiated multicenter trial will prospectively record all data on performed CERAB procedures using the Bentley balloon expandable covered stents (BeGraft Aortic and BeGraft Peripheral) in multiple International sites, in order to gain more robust real-world data on the efficacy of these stent grafts for this indication.
Consecutive patients in whom a CERAB will be performed with these particular covered stents in the participating centers.
Main study parameters/endpoints: The primary end-point of this study is technical success. Patency rates, peri-procedural morbidity, clinical improvement, quality of life, clinically-driven target vessel revascularization and reintervention-rate will be secondary outcome measures. Overall, patients will be followed for 5 years
- Detailed Description
Endovascular treatment is rapidly taking over surgery for aorto-iliac occlusive disease (AOID) also for complex lesions. This is related to the minimally invasiveness of the procedure decreasing the morbidity rate. Patency results of endovascular treatment were often inferior compared to open repair when the aortic bifurcation was involved in the lesion. In 2013 Covered Endovascular Reconstruction of the Aortic Bifurcation (CERAB) technique was introduced in an attempt to improve endovascular treatment results by a more anatomical and physiological reconstruction, with a subsequent better clinical outcome. The early results of the CERAB configuration are promising with primary, primary-assisted and secondary patency of, respectively 86.2%/91.1%/97.0% at 1-year, 83.9%/88.7%/97.0% at 2-year and 82.1%/86.8%/97.0% at 3-year FU in a group of 130 patients, including the first in man results. The vast majority (89.2%) were TASC-II D lesions and the 30-day major complication rate was 7.7%.
This trial is designed to prospectively collect all data on implanted CERAB configurations, using the balloon expandable stents from Bentley InnoMed, in a defined group of aorto-iliac pathology in multiple international sites in order to gain more insight in the outcome of the technique. Technical success will be the primary endpoint. Other evaluations will include patency rates, quality of life, the reintervention-rate, 30-day morbidity and target vessel revascularization up to 5 years after treatment.
A total of 145 patients will be included and followed until 5 years of follow-up. A core lab will independently analyze the images (CT scan or duplex) which will be made at the following time points: pre-op, 1 month, 6 months, 1 year and yearly up to 5 years of follow-up.
Additionally, at these time points three questionnaires will be completed by the patients. These questionnaires are about walking ability (WIQ), and quality of life (EQ-5D and WHOQoL-BREF).
Recruitment & Eligibility
- Status
- TERMINATED
- Sex
- All
- Target Recruitment
- 28
- Age 18 years or older
- Provided written informed consent
- Clinical necessity for treatment
- Eligible anatomy for CERAB without the need for chimney's
- TASC-2 classification as assigned in the study protocol (specified type B, C and D lesions)
- Patient is participating in another conflicting clinical study
- Patient's life expectancy <2 years as judged by the investigator
- Patient has a psychiatric or other condition that may interfere with the study
- Patient has a known allergy to any device component
- Patients with a systemic infection who may be at increased risk of endovascular graft infection.
- Patient has a coagulopathy or uncontrolled bleeding disorder
- Patient had a CVA or an MI within the prior three months
- Patient is pregnant (Female patients of childbearing potential only)
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Primary Outcome Measures
Name Time Method Primary patency Up to 12 months Primary patency at 12 months measured by duplex ultrasound
Technical success Up to 30 days Technical success is defined as successful implantation of the CERAB device without conversion to open repair
- Secondary Outcome Measures
Name Time Method Clinical success Up to 5 years of follow-up Patient reported outcomes measured by the WHOQoL Bref
Technical success Up to 5 years of follow-up Conversion to open surgery judged at every clinic visit by the investigator
Trial Locations
- Locations (8)
Spanish Hospital
🇲🇽Mexico City, Mexico
Auckland City Hospital
🇳🇿Auckland, New Zealand
Waikato Hospital
🇳🇿Hamilton, New Zealand
A.O.U. Città della Salute e della Scienza di Torino
🇮🇹Torino, Italy
Medical University Center Maastricht
🇳🇱Maastricht, Netherlands
Dandenong Hospital
🇦🇺Victoria Point, Australia
Rijnstate Hospital
🇳🇱Arnhem, Gelderland, Netherlands
Dijklander Ziekenhuis
🇳🇱Hoorn, Netherlands