Covered Endovascular Reconstruction of Aortic Bifurcation (CERAB) for Extensive Aortoiliac Occlusive Disease A Multicenter, Prospective Investigator Initiated Trial
试验速览
- 阶段
- 不适用
- 状态
- 终止
- 发起方
- 入组人数
- 28
- 试验地点
- 8
- 主要终点
- Primary patency
研究概览
简要总结
Endovascular treatment is rapidly taking over surgery for aorto-iliac occlusive disease (AOID), also in extensive pathology. This is related to its minimally invasiveness, decreasing the procedural morbidity rate. When the aortic bifurcation was involved in the lesion, the patency rates of kissing stents configurations were often inferior to open repair. In 2013 the Covered Endovascular Reconstruction of the Aortic Bifurcation (CERAB) technique was introduced in an attempt to improve endovascular treatment results by a more anatomical and physiological reconstruction, with a subsequent improved clinical outcome.
This investigator-initiated multicenter trial will prospectively record all data on performed CERAB procedures using the Bentley balloon expandable covered stents (BeGraft Aortic and BeGraft Peripheral) in multiple International sites, in order to gain more robust real-world data on the efficacy of these stent grafts for this indication.
Consecutive patients in whom a CERAB will be performed with these particular covered stents in the participating centers.
Main study parameters/endpoints: The primary end-point of this study is technical success. Patency rates, peri-procedural morbidity, clinical improvement, quality of life, clinically-driven target vessel revascularization and reintervention-rate will be secondary outcome measures. Overall, patients will be followed for 5 years
详细描述
Endovascular treatment is rapidly taking over surgery for aorto-iliac occlusive disease (AOID) also for complex lesions. This is related to the minimally invasiveness of the procedure decreasing the morbidity rate. Patency results of endovascular treatment were often inferior compared to open repair when the aortic bifurcation was involved in the lesion. In 2013 Covered Endovascular Reconstruction of the Aortic Bifurcation (CERAB) technique was introduced in an attempt to improve endovascular treatment results by a more anatomical and physiological reconstruction, with a subsequent better clinical outcome. The early results of the CERAB configuration are promising with primary, primary-assisted and secondary patency of, respectively 86.2%/91.1%/97.0% at 1-year, 83.9%/88.7%/97.0% at 2-year and 82.1%/86.8%/97.0% at 3-year FU in a group of 130 patients, including the first in man results. The vast majority (89.2%) were TASC-II D lesions and the 30-day major complication rate was 7.7%.
This trial is designed to prospectively collect all data on implanted CERAB configurations, using the balloon expandable stents from Bentley InnoMed, in a defined group of aorto-iliac pathology in multiple international sites in order to gain more insight in the outcome of the technique. Technical success will be the primary endpoint. Other evaluations will include patency rates, quality of life, the reintervention-rate, 30-day morbidity and target vessel revascularization up to 5 years after treatment.
A total of 145 patients will be included and followed until 5 years of follow-up. A core lab will independently analyze the images (CT scan or duplex) which will be made at the following time points: pre-op, 1 month, 6 months, 1 year and yearly up to 5 years of follow-up.
Additionally, at these time points three questionnaires will be completed by the patients. These questionnaires are about walking ability (WIQ), and quality of life (EQ-5D and WHOQoL-BREF).
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Age 18 years or older
- •Provided written informed consent
- •Clinical necessity for treatment
- •Eligible anatomy for CERAB without the need for chimney's
- •TASC-2 classification as assigned in the study protocol (specified type B, C and D lesions)
排除标准
- •Patient is participating in another conflicting clinical study
- •Patient's life expectancy <2 years as judged by the investigator
- •Patient has a psychiatric or other condition that may interfere with the study
- •Patient has a known allergy to any device component
- •Patients with a systemic infection who may be at increased risk of endovascular graft infection.
- •Patient has a coagulopathy or uncontrolled bleeding disorder
- •Patient had a CVA or an MI within the prior three months
- •Patient is pregnant (Female patients of childbearing potential only)
结局指标
主要结局
Primary patency
时间窗: Up to 12 months
Primary patency at 12 months measured by duplex ultrasound
Technical success
时间窗: Up to 30 days
Technical success is defined as successful implantation of the CERAB device without conversion to open repair
次要结局
- Clinical success(Up to 5 years of follow-up)
- Technical success(Up to 5 years of follow-up)
研究者
Michel Reijnen
Principal Investigator
Rijnstate Hospital