Lipiflow vs iLux Patient Acceptance and Comfort Study
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 43
- 试验地点
- 2
- 主要终点
- Procedure Comfort
研究概览
简要总结
This study was designed to compare patient acceptance, comfort, and preference between two meibomian gland clearing devices (Lipiflow vs, iLux). Primary Objective was to compare patient comfort as assessed by Likert-style scale questionnaire following each bilateral procedure. Secondary Objective was to compare overall experience and treatment preference as assessed by Likert-style questionnaire following each bilateral procedure. Both devices are exempt from IDE regulations [21 CFR 812.2(c)].
详细描述
Introduction Meibomian gland disease (MGD) is increasingly recognized as a primary cause or contributor to tear instability and dry eye disease. Effective management of this disorder often requires meibomian gland expression and clearance. A variety of devices which apply pressure, heat or a combination of both to the glands have been used.
Two such devices that apply heat and pressure simultaneously are commercially available. LipiFlow (JNJ Vision Care) is an automated computer-controlled device that uses vectored thermal (hydraulic) pulsation applied by an activator device placed on the eye between the globe and the eyelids to achieve gland clearance. The iLux System (Alcon) is an operator controlled assisted manual device which applies heat generated by infrared LEDs and expression through cam driven mechanical pressure applied to the lids.
Device Descriptions LipiFlow Thermal Pulsation System
The Lipiflow Thermal Pulsation System is a commercially available device used in the treatment of MGD. It is cleared to be marketed by the United States Food and Drug Administration. The LipiFlow Thermal Pulsation System is intended for the application of localized heat and pressure therapy in adult patients with chronic cystic conditions of the eyelids, including meibomian gland dysfunction (MGD), also known as evaporative dry eye or lipid deficiency dry eye.
The LipiFlow Console provides the user interface and control elements of the system, including all software, algorithms and control elements. The Activator, a single-use sterile device, delivers automated therapeutic energies to each meibomian gland. Its contoured design vaults the cornea and protects the eye allowing a maximum therapeutic temperature of 43 degrees Celsius to reach glands from the inner eyelid, without damaging the eyelid or delicate structures of the globe. Insulation protects the cornea from exceeding a safe 39.5 degrees Celsius, while a pressure feedback loop sends pulsed sequences to expel blockages. Force equalization protects the globe from pressure transmission by focusing energy only on the eyelid. Delivered through the LipiFlow Activator, Vectored Thermal Pulse™ (VTP) technology applies a combination of heat and pressure to the inner eyelid to safely remove gland obstructions and stagnant gland content. Vectored heat and adaptive force equalization target the pulse, heat, and pressure on the meibomian glands to maximize effectiveness. Therapeutic motion provides proximal-to-distal peristalsis to clear gland contents.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Crossover
- 主要目的
- Other
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Subject can be of any gender or race
- •Subject must be 18 years of age or older at the time of informed consent
- •Subject must be able to understand and must sign an Informed Consent that has been approved by an IRB
- •Subject must have confirmed diagnosis of Meibomian Gland Dysfunction
- •Subject must agree to not wear contact lenses the day of the Study visit
排除标准
- •History of intraocular or oculoplastic surgery within 6 months of Screening visit
- •History of ocular injury or trauma, chemical burns, or limbal stem cell deficiency within 3 months of the Screening visit
- •Active ocular infection or active ocular inflammation (including allergic conjunctivitis, vernal or giant papillary conjunctivitis) at time of Screening visit
- •History of ocular surface abnormality that may compromise corneal integrity
- •History of treatment with LipiFlow or iLux in either eye in the last 6 months
- •Allergy to topical proparacaine eye drops
结局指标
主要结局
Procedure Comfort
时间窗: 5 minutes
Likert-scale questionnaire: 1=strongly disagree, 2=disagree, 3=Undecided, 4=Agree, 5=strongly agree - 1 Question
次要结局
- Patient Preference(5 minutes)
- Procedure Experience(5 minutes)
研究者
Dr. Arthur Epstein
Director of Dry Eye and Ocular Surface Disease
Epstein, Arthur B., OD, FAAO