跳至主要内容
临床试验/NCT02397668
NCT02397668招募中不适用

CorMatrix Cor TRICUSPID ECM Valve Replacement Study

CorMatrix Cardiovascular, Inc.8 个研究点 分布在 1 个国家目标入组 78 人开始时间: 2022年8月1日最近更新:
适应症

试验速览

阶段
不适用
状态
招募中
入组人数
78
试验地点
8
主要终点
Procedural Success

研究概览

简要总结

The Pivotal Study of the Cor TRICUSPID ECM Valve (or Cor PEDIATRIC Tricuspid ECM Valve). This study follows the EFS and is now to determine the safety and efficacy of the Cormatrix Cor TRICUSPID Valve for any patients requiring surgical replacement of the tricuspid valve.

详细描述

CorMatrix Cardiovascular, Inc. has developed a device for heart valve replacement, the CorMatrix® Cor ECM® Tricuspid Valve, which can be implanted to replace dysfunctional tricuspid heart valves. This Pivotal Study is being performed to verify the ability to successfully implant the Tricuspid Valve, the clinical safety of the device, and whether the device performs its intended use. The study is a multi-center, prospective, single-arm, Pivotal Study of subjects receiving the Cor TRICUSPID ECM Valve or Cor PEDIATRIC Tricuspid ECM Valve. The study will be conducted at up to 15 sites.

Up to 60 subjects will undergo tricuspid valve replacement (TVR) with the CorMatrix ECM Valve for the surgical management of tricuspid valve disease. The cohort will include up to 60 adult and 18 pediatric patients.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
1 Year 至 85 Years(Child, Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patient with a regurgitant or absent tricuspid valve requiring surgical treatment including those patients having concomitant cardiac procedures
  • Male or female
  • Patient/authorized legal guardian understands the nature of the procedure, is willing to comply with associated follow-up evaluations, and provides written informed consent and the pediatric patient (if applicable) provides written assent (if able) prior to procedure
  • Patient/patient's authorized legal guardian is geographically stable (or willing to return for required study follow-up) and understands and is willing to fulfill all of the expected requirements of this clinical protocol
  • Children with congenital disease where the Cor PEDIATRIC Tricuspid ECM Valve would be the physiological right-sided valve

排除标准

  • Tricuspid annulus too small (< 10mm) to accommodate the Cor Tricuspid ECM Valve
  • Left ventricular ejection fraction (LVEF) < 25%
  • Mean pulmonary pressure > 50mm Hg or pulmonary vascular resistance greater than 6 Woods Units
  • Emergency cardiac procedure. An example would be a person requiring resuscitation and in cardiogenic shock. An unscheduled or unplanned emergency surgery
  • Cardiac transplant patient
  • Acute transmural myocardial infarction (MI) within 7 days of enrollment that results in cardiogenic shock
  • Patients with a single ventricle where the Cor Tricuspid ECM Valve would be the systemic AV valve
  • Documented primary coagulopathy or uncorrected platelet disorder, including thrombocytopenia (absolute platelet count <30k). Patient can be enrolled regardless of these parameters if in the opinion of the Investigating Surgeon the coagulopathy can be adequately reversed by transfusions. An example would be the reversal of thrombocytopenia by transfusion of platelets
  • Documented evidence of intrinsic hepatic disease (defined as liver enzyme values (aspartate aminotransferase (AST), alanine aminotransferase (ALT), or total bilirubin) that are > 5 times the upper limit of reference range within 30 days of enrollment, except in association with acute/reversible decompensation as determined by the Investigator)
  • Documented evidence of significant renal dysfunction (serum creatinine > 4.0mg/dl or GFR< 30 on the modified Schwartz formula)
  • Stroke within 30 days prior to enrollment
  • Major or progressive non-cardiac disease (liver failure, renal failure, cancer (CA)) that has a life expectancy of less than one year
  • Known cancer (cancer-free <1 year; does not include non-metastatic basal cell carcinoma or cervical carcinoma) and/or undergoing treatment including chemotherapy and radiotherapy
  • Hematological disorders (e.g., aplastic anemia) or patients taking bone marrow suppressant drugs
  • Known sensitivity to porcine materials
  • Contraindication to anticoagulation/antiplatelet therapy (aspirin (ASA) and/or Plavix)
  • Patients who are pregnant (method of assessment Investigator's discretion)
  • Patients who are currently enrolled in another investigational study or registry that would directly impact the treatment or outcome of the current study, without CorMatrix written approval

结局指标

主要结局

Procedural Success

时间窗: 30 days postop

Device Success and No TV device- or TV procedure-related SAE's

次要结局

  • Device Success(30 day and all follow up time points)
  • Technical Success(within 24 hours)

研究者

申办方类型
Industry
责任方
Sponsor

研究点 (8)

Loading locations...

相似试验