Preemer Trial - Prophylactic Mesh Versus no Mesh in the Midline Emergency Laparotomy Closure for Prevention of Incisional Hernia: a Multi Center, Double-blind, Randomized Controlled Trial
- Conditions
- Emergency LaparotomyHernia PreventionIncisional HerniaMidline Laparotomy
- Interventions
- Device: Prophylactic self gripping meshDevice: Slowly absorbable continuous monofilament suture
- Registration Number
- NCT04311788
- Lead Sponsor
- University of Oulu
- Brief Summary
244 patients, who have an emergency midline laparotomy for any gastrointestinal reason, will be randomized in a 1:1 ratio either to mesh group with a retrorectus prophylactic self-gripping mesh or to control group with 4:1 small stitch closure by continuous monofilament suture. They will be followed up at 30 days, 2 and 5 years to detect the incidence of incisional hernia.
- Detailed Description
Incisional hernia (IH) is a common complication of abdominal wall surgery. Its' incidence varies greatly (2-30 %) among studies. The incisional hernia incidence is influenced by several factors, such as closing technique, follow-up time and the modality of radiological investigations, patient characteristics and co-morbidities as well as indication and type for surgery.
European Hernia Society (EHS) guideline strongly recommends to utilise a non-midline approach to a laparotomy whenever possible to decrease the incidence of incisional hernia. However, this is clearly not an option in an emergency laparotomy, as midline incision is the fastest and the best visualizing opening to explore the whole abdominal cavity in an emergency setting.
For elective midline incisions, evidence-based recommendation is to perform a continuous suturing technique with slowly absorbable monofilament suture when closing the incision. Suturation should be done performing a single layer aponeurotic closure technique without separate closure of the peritoneum. A small bites technique with a suture to wound length (SL/WL) ratio at least 4:1 is the current recommended method of fascial closure.
Prophylactic mesh augmentation in a non-emergency setting appears effective and safe and can be suggested for high-risk patients. However, no recommendations can be given on the optimal technique to close emergency laparotomy incisions because of lack of evidence. This problem should be emphasized on due to high rates of IH after emergency laparotomy. All this makes the use of prophylactic mesh in the emergency setting an interesting proposition, as it may decrease the rate of IHs. However, there are concerns over potential mesh related complications including infection, chronic pain, seromas and bowel fistulas especially in emergency situations like peritonitis and intestinal obstruction. There is preliminary evidence published about the safety and efficiency of the prevention of IHs using meshes in the emergency laparotomy closure even in contaminated conditions.
In the resent systematic review and meta-analysis, only results of 2 studies and altogether 299 patients were eligible for the analysis. Swiss case-control study reported an IH rate of 3,2% (2/63) in the mesh group and 28,6% (20/70) in the control group. Spanish study group had the same kind of results in their retrospective cohort; IH rate of 5,9% (3/50) in the mesh group and 33,3% (33/100) in the control group. There was no statistically significant difference in the incidence of surgical site infection or other complications when prophylactic mesh group was compared to standard closure group. SSI rate in Swiss study was 60% and respectively only 17% in the Spanish study. This may reflect differences in the patient selection, therefore the safety profile of the prophylactic mesh in the emergency setting has not been adequately described. Neither of the studies included in meta-analysis were not randomized controlled trials. There were also many methodological differences including patient selection, used mesh, and mesh placement. Thus, the conclusion of the systematic review paper was that there are limited data to assess the effect or safety of the use of prophylactic mesh in the emergency laparotomy setting. Randomized control trials are required to address this important clinical question. EHS guideline group resulted the same conclusion in their recommendation report.
There are about 1650 patients are operated in Finland because of IH every year. According to the European study, the estimated cost for IH surgery is 6450 euros. The corresponding costs in Sweden were even higher reaching 9060 euros per treatment. Extrapolated to Finland, this means that operative treatment of IHs cause more than 10 million expenses to the Finnish health care sector in a year. Some of these costs may be avoidable by using the prophylactic mesh during the closure of midline emergency laparotomies in the patients with IH risk factors.
Recruitment & Eligibility
- Status
- ACTIVE_NOT_RECRUITING
- Sex
- All
- Target Recruitment
- 109
- Midline emergency laparotomy for any gastrointestinal indication
-
• Previous ventral hernia repair with mesh in the midline
-
Previous inguinal or femoral hernia repair by any technique with mesh is accepted
- Previous WHO class of physical activity 3-4 (WHO 3 more than 50% of time at rest, WHO 4 stays at rest most of the time)
- Relaparotomy
- Indication for laparotomy is incarcerated hernia
- Pregnant or suspected pregnancy
- <18 years
- Metastastic malignancy of any origin
- Planned osteomyelitis
- Patients living geographically distant and/or unwilling to return for follow-ups
- No informed consent
- Subject participates in another RCT Intra-operative exclusion criteria applicable for both randomization groups
- Abdomen is left open
- Second look laparotomy planned
- Ostomy created at the operation
- Inability to keep the mesh securely out of the peritoneal cavity or close the anterior fascia
- Intra-abdominal malignancy diagnosed at the operation
- >2 cm hernia in midline
-
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Arm && Interventions
Group Intervention Description Intervention group Prophylactic self gripping mesh Prophylactic self gripping mesh (Program, Medtronic) will be placed in rectorectus space to prevent incisional hernia. Control group Slowly absorbable continuous monofilament suture Abdomen of the patients in the control group will be closed by using small stitch closure with suture to wound length of 4:1 and slowly absorbable monofilament suture.
- Primary Outcome Measures
Name Time Method Incidence of incisional hernia 2 years Incidence of incisional hernia, either symptomatic or asymptomatic detected clinically and/or radiologically
- Secondary Outcome Measures
Name Time Method Quality of life by RAND-36 5 years Quality of life defined by RAND-36
Quality of life by AAS 5 years Quality of life defined by AAS questionnaire
Comprehensive Complication Index 30 days Comprehensive Complication Index
Surgical site infection (SSI) rate 30 days Surgical site infection (SSI) rate defined by CDC classification of surgical site infection
Fascial rupture 30 days Incidence of fascial rupture
Incisional hernia 5 years Incisional hernia incidence during long-term follow-up
Incisional hernia repair rate 5 years Incisional hernia repair rate during follow-up
Re-operations 5 years Re-operations due to mesh- or hernia related indications
Quality of life by Promis 5 years Quality of life defined by Promis questionnaire
Cost analysis 5 years All differences in costs between the groups will be analyzed
Trial Locations
- Locations (7)
Jorvi Hospital
🇫🇮Espoo, Finland
Turku University Hospital
🇫🇮Turku, Finland
Lahti Central Hospital
🇫🇮Lahti, Finland
Oulu University Hospital
🇫🇮Oulu, Finland
Seinäjoki Central Hospital
🇫🇮Seinäjoki, Finland
Helsinki University Hospital
🇫🇮Helsinki, Finland
Tampere University Hospital
🇫🇮Tampere, Finland