Evaluation of 3D Translabial Ultrasound Imaging for Pessary Size Estimation

Western University, Canada1 site in 1 country21 target enrollmentDecember 18, 2019

Overview

Phase
Not Applicable
Intervention
Not specified
Conditions
Pelvic Organ Prolapse
Sponsor
Western University, Canada
Enrollment
21
Locations
1
Primary Endpoint
3D ultrasound images and pressure/volume measurements of vagina in patients with pelvic organ prolapse
Status
Terminated
Last Updated
2 years ago

Overview

Brief Summary

This is a feasibility study looking at the use of 3D ultrasound with vaginal manometry at various distension volumes to predict the best available pessary for successful fit.

Detailed Description

Patients who are currently using a pessary for management of pelvic organ prolapse and who are able to remove/replace the pessary themselves will be approached for recruitment. The pessary will be removed two days prior to 3D translabial ultrasound. The vagina will be distended with a pressurized compliant bag with concurrent pressure and volume measurements. Translabial ultrasound will be used to measure structural parameters within the vagina at varying pressures/volumes. The volume, pressure and structural parameters measured will be compared to dimensions of the patient's own pessary to develop mathematical models to predict the best available pessary choice for the patient.

Registry
clinicaltrials.gov
Start Date
December 18, 2019
End Date
November 17, 2023
Last Updated
2 years ago
Study Type
Interventional
Study Design
Single Group
Sex
Female

Investigators

Sponsor
Western University, Canada
Responsible Party
Sponsor

Eligibility Criteria

Inclusion Criteria

  • are current pessary users (\> 6 months) who have no pessary related complication, including discomfort, vaginal bleeding, and pessary extrusion
  • are able to provide informed consent
  • can perform self-care, i.e. removing and inserting the pessary themselves
  • are willing to remove their pessary two days before the ultrasound examination date

Exclusion Criteria

  • inability to give informed consent
  • inability to communicate with the person performing the consent and the sonographer performing ultrasound scanning
  • history of pelvic radiation or surgery (excluding hysterectomy)
  • using pessaries other than ring, incontinence dish, donut, Shaatz
  • inability to perform the Valsalva maneuver or pelvic floor contraction
  • restricted mobility that prevents them from ambulating to assess the comfort level of the pessary during the initial pessary fitting visit
  • lack of sensation at the pelvic floor
  • being pregnant at the time of the examination

Outcomes

Primary Outcomes

3D ultrasound images and pressure/volume measurements of vagina in patients with pelvic organ prolapse

Time Frame: 1 hour and 20 minutes (i.e. the estimated time for the ultrasound and manometry examination per participant).

3D ultrasound images of the vaginal canal and the pelvic floor will be obtained using various ultrasound probes. Pressure and volume measurements (i.e. manometry) will be obtained using a urodynamic system.

Secondary Outcomes

  • Survey(5 minutes)

Study Sites (1)