跳至主要内容
临床试验/NCT04799470
NCT04799470招募中不适用

Novel DBS Stimulation Patterns for Treatment of Parkinson's Disease - UNMC/Medtronic Collaborative Acute Feasibility Pilot

University of Nebraska2 个研究点 分布在 1 个国家目标入组 10 人开始时间: 2021年5月10日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
招募中
入组人数
10
试验地点
2
主要终点
Safety and Tolerability of novel DBS stimulation patterns.

研究概览

简要总结

This is an open-label, non-randomized, proof-of-concept comparison of clinical vs. research stimulation patterns in patients with Parkinson's disease (PD) being treated with Deep Brain Stimulation (DBS) through the Medtronic Percept PC DBS device. The investigators hypothesize that stimulation patterns designed to better target excessive synchrony in a patient-tailored manner may result in more efficient and effective therapy with fewer side effects. Medtronic 3rd-generation sensing implantable neural stimulator, Percept PC, is FDA-approved for treating PD. The Percept PC device features BrainSense, the first and only available sensing technology for deep brain stimulation. BrainSense technology allows the device to capture and record brain signals (local field potentials, or LFP) using the brain-implanted DBS lead, while simultaneously delivering therapeutic stimulation. Investigators plan to enroll and complete investigations in 15 study subjects total, who have been previously implanted with the Medtronic Percept PC for the treatment of PD, and who are optimized for clinical stimulation and anti-Parkinsons medication. Investigations will be performed in UNMC Movement Disorders Clinic, UNMC Neurosurgery Lab, and UNO Biomechanics Research Building, Gait Lab. Subjects will receive research stimulation patterns and the effect on PD motor symptoms will be assessed via Unified Parkinsons Disease Rating Scale (UPDRS)-part III and gait measures. Videotaping of patient UPDRS-III testing and gait will be obtained.

详细描述

Parkinson's disease (PD) is a neurodegenerative disorder characterized by both motor and non-motor symptoms. Motor symptoms of PD include the clinical triad of tremor, rigidity, and bradykinesia, and typically lead to the initial diagnosis. While there is yet no cure for PD, medical and surgical therapies have been developed that effectively target the motor symptoms of PD. Patients with PD who demonstrate significant motor fluctuations and dyskinesia are considered for subthalamic nucleus (STN) deep brain stimulation (DBS) surgery. Therapeutic DBS leads to a reduction in pathological neuronal synchronization seen in PD. While continuous high-frequency stimulation is effective for ameliorating motor symptoms, the investigators hypothesize that different stimulation patterns which are designed to better target excessive synchrony in a patient-tailored manner, may result in more efficient and effective therapy with fewer side effects. This overarching hypothesis is supported by prior foundational preclinical and clinical research. Medtronic has developed proprietary technology that allows implantable neural stimulators (INS) to deliver both standard clinical electrical stimulation therapy and to record bioelectric data (i.e. local field potentials; LFPs) through DBS leads implanted in the brain. Medtronic's 3rd-generation sensing DBS INS, Percept PC, is FDA-approved for treating PD and can be used to explore unique biomarkers of brain state changes associated with activities of daily living and disease symptomatic states.

This research will use Percept PC INS latent capabilities to deliver research stimulation. Importantly, all stimulation in this research project will be delivered using charge-balanced pulses, in compliance with all FDA safety guidelines including frequency (≤ 250 Hz) and charge density (30 µC/cm2/phase). At the conclusion of the research study, standard clinical stimulation will be re-activated.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
19 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients with idiopathic Parkinson's Disease who were recommended for STN DBS using standard clinical inclusion and

排除标准

  • (e.g., presence of coagulopathy, dementia, untreated depression, pre-existing implanted stimulation system, prior intracranial surgery, history of alcohol or drug abuse)
  • Patients have been previously implanted with bilateral STN DBS and the Medtronic Percept PC implantable neural stimulator.
  • Patients are optimized for clinical stimulation and medication for at least 3 months post-surgery for the implantation of their DBS system.
  • Consent to study participation
  • Presence of a robust beta peak (detectable using the Percept BrainSense Survey feature; ≥ 0.7 µV/rtHz), intra-operatively (assessed via Lead Confirm technology from Alpha Omega)
  • Good response to stimulation (30% improvement on UPDRS III compared to baseline OFF), at least 3 months post-surgery.
  • Exclusion Criteria:
  • Not currently implanted with the Medtronic Percept INS
  • Not willing to participate in the study
  • Unstable stimulation with need for frequent reprogramming or further adjustment
  • Significant stimulation-induced side effects
  • Need for unusual programming parameters such as very high (> 200 Hz) or low (< 100) frequencies (due to cycle limitations)
  • The patient has an implanted cardiac device
  • The patients Medtronic Percept TM PC indicates elective-replacement-indicated (ERI) at the start of the study

研究组 & 干预措施

PD with DBS

Experimental

Patients with Parkinson's Disease who were implanted with Medtronic Percept PC for DBS and consent to participate in the study.

干预措施: Novel DBS stimulation patterns (Device)

结局指标

主要结局

Safety and Tolerability of novel DBS stimulation patterns.

时间窗: Years 1-2

To assess if the novel stimulation patterns provide similar side effect profile, when compared to standard clinical stimulation, tolerability will be assessed by: 1. Number of study participants experiencing stimulation-related side effects. Side effects will be measured as patient-reported severity and type of side effect. 2. Number of study participants experiencing stimulation-related Adverse Events.

次要结局

  • Response to novel DBS stimulation patterns.(Years 1-2)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验