Evaluation of Intraoperative Carotid Peak Systolic Velocity Variability in Liver Transplant Patients
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 42
- 试验地点
- 1
- 主要终点
- CPSVv
研究概览
简要总结
The aim of this study was to evaluate carotid peak systolic velocity variability using intraoperative ultrasound and to determine whether this method is useful in the assessment of hemodynamic status and intravascular volume in liver transplantation. Previously, a similar study was performed in liver transplant intensive care unit, but no study was performed to evaluate intraperative fluid status with carotid ultrasonography.
详细描述
Aim: The aim of this study was to evaluate carotid peak systolic velocity variability using intraoperative ultrasound and to determine whether this method is useful in the assessment of hemodynamic status and intravascular volume in liver transplantation. Previously, a similar study was performed in liver transplant intensive care unit, but no study was performed to evaluate intraperative fluid status with carotid ultrasonography.
Material and Method: Our prospective, single-center study was conducted at the Inonu University Faculty of Medicine, Turgut Ozal Medical Center Liver Transplant Institute, between Semtember 18, 2023, and April 29, 2024. After excluding patients with fulminant hepatic failure requiring emergency transplantation and those outside the age range of 18-65 years, 42 patients out of a total of 89 liver transplant recipients were included. Masimo non-invasive probe was inserted for pleth variable index (PVI), perfusion index (PI), oxygen reserve index (ORI), SpHb measurement and input values were recorded. After invasive arterial monitoring, which is routinely performed in transplant patients, cardiac output, stroke volume, stroke volume variation, dPmax were monitored by pulse contour analysis method and values were recorded. At the beginning of the dissection phase, carotid ultrasound was performed and values were recorded (T0). After the portal vein and v. cava inf. were clamped (anhepatic period), carotid ultrasound was performed and values were recorded (T1). Hemodynamic, respiratory, routine laboratory data and hourly urine output were recorded throughout the operation.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 65 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Adult patients scheduled for elective liver transplantation
排除标准
- •fulminant hepatic failure requiring emergency transplantation, patients with carotid artery disease
研究组 & 干预措施
Liver transplant recipients
After excluding patients with fulminant hepatic failure requiring emergency transplantation and those outside the age range of 18-65 years, 42 patients out of a total of 89 liver transplant recipients were included.
结局指标
主要结局
CPSVv
时间窗: During surgery: T0: Before vena cava inferior clamping T1: After vena cava inferior clamping
carotid peak systolic velocity variability
次要结局
未报告次要终点
研究者
Yusuf Ziya ÇOLAK
associate professor
Inonu University
