Comparison Between Point of Care Device and Venous Blood International Normalized Ratio Measurements for Pediatric Patients on Anticoagulation Therapy.
试验速览
- 阶段
- 1 期
- 状态
- 终止
- 入组人数
- 200
- 试验地点
- 2
- 主要终点
- The compariative accuracy between Point of Care device and standard of care method of determining PT/InR (Laboratory testing using Venous blood Draw)
研究概览
简要总结
Investigate the validity of Hemosense System in pediatric patients on anticoagulation therapy.
详细描述
Over the last few decades there has been an increased use of Warfarin in the pediatric population stemming from the use of mechanical heart valves and palliative surgical procedures requiring anticoagulation therapy. Other patients with enzymatic deficiency within the coagulation cascade may develop thrombosis treated with anticoagulation, i.e. factor V Leiden deficiency. Prevention of poor outcome from thrombosis has required closer monitoring in the pediatric patient. In addition, absorption of Warfarin in the pediatric population is highly variable and depends on the child's age, weight, diet, and concurrent use of other medications (Desai, 2000). This makes achieving anticoagulation very difficult. "Because of the intrinsic differences in the coagulation systems in children and adults, guidelines for antithrombotic therapy in adults cannot be extrapolated to pediatrics" (Desai, 2000). Therefore, pediatric patients on anticoagulation therapy require frequent lab work to monitor their prothrombin time and international ratios (PT/INR).
There are a number of barriers to care when discussing anticoagulation therapy for pediatric patients. Frequent venous blood draws represent a painful procedure that elicit anxiety and fear which leads to noncompliance. In addition, children are more difficult to obtain blood samples because of smaller vessels, patient movement during procedure, and the volume of blood that is required for the test. Other barriers include the time delay from when the patient has the lab work drawn, to when the result get to the provider for any patient care decisions to be made.
There are a number of Point of Care devices available for near-patient testing of the PT/InR's that requires only a finger stick. These monitors have been validated against standardized laboratory testing, in order for the monitor to be certified by the FDA. Similar studies to validate finger stick methods in pediatric patients have not been completed. The aim of this project is to validate the accuracy of Hemosense, a point of care device, to venous blood PT/InR level in the pediatric population.
研究设计
- 研究类型
- Interventional
- 分配方式
- Non Randomized
- 干预模型
- Single Group
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 1 Day 至 18 Years(Child, Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •All pediatric patient requiring Warfarin therapy.
排除标准
- •Subjects older then 18 year of age.
- •Pregnant subjects.
结局指标
主要结局
The compariative accuracy between Point of Care device and standard of care method of determining PT/InR (Laboratory testing using Venous blood Draw)
次要结局
未报告次要终点