MedPath

Influence of capsular tension ring on intracapsular stability and visual function after implantation of multifocal intraocular lens

Not Applicable
Conditions
cataract
Registration Number
JPRN-UMIN000035993
Lead Sponsor
niversity of Tsukuba
Brief Summary

Throughout the 12-month follow-up period, there was no significant difference in refractive and visual outcomes between groups. The amount of IOL decentration was significantly larger in eyes with CTR. There was a significant negative correlation between capsular bag diameter and the amount of IOL decentration in eyes with CTR, but not in eyes without CTR. CTR coimplantation increased IOL decentration possibly due to the interference between CTR eyelets and IOL haptics.

Detailed Description

Not available

Recruitment & Eligibility

Status
Complete: follow-up complete
Sex
All
Target Recruitment
22
Inclusion Criteria

Not provided

Exclusion Criteria

Eyes with other ocular diseases

Study & Design

Study Type
Interventional
Study Design
Not specified
Primary Outcome Measures
NameTimeMethod
Stability of intraocular lens 3 months after surgery
Secondary Outcome Measures
NameTimeMethod
Visual function 3 months after surgery