跳至主要内容
临床试验/NCT03900039
NCT03900039已完成不适用

Randomized Control Trial of Four Bearing Surfaces in Primary Total Hip Arthroplasty in Patients Over the Age of 18 Years

Unity Health Toronto1 个研究点 分布在 1 个国家目标入组 100 人开始时间: 2005年7月26日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
100
试验地点
1
主要终点
Wear rates of polyethylene over 10 years

研究概览

简要总结

The aim of the study is to assess the ideal bearing surfaces in hip replacement by comparing 4 different combinations. In a hip replacement this means what the head and the socket liner are made of.

详细描述

In hip replacements, arguably the most important thing for survivorship is what rubs against what.

Traditionally surgeons used metal (Cobalt-Chrome) against a conventional polyethylene (plastic). More recently (around 15 years ago) a newer more dense type of polyethylene (called XLPE) had been developed and a new type of head called Oxidized Zirconium was also developed.

In this trial, adults who were undergoing hip replacements were randomized assigned into one of the four groups:

Group 1: old plastic vs metal head Group 2: Old plastic against Oxidized Zirconium Group 3: New plastic versus metal head Group 4 New plastic vs Oxidized Zirconium

All patients were followed up for a minimum of 10 years to assess which group wore the most amount of polyethylene and which group had the best survival rate.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Health Services Research
盲法
Single (Outcomes Assessor)

盲法说明

The assessment of the implants was done by a secondary center that was unaware of which the bearing type was in which patient.

入排标准

年龄范围
18 Years 至 65 Years(Adult, Older Adult)
性别
All
接受健康志愿者
是

入选标准

  • •All adults with no history of cancer, infection of the hip and with the capacity to make informed consent for the trial

排除标准

  • •those under the age of 18 and over
  • •Those with a history of cancer and infection. Those without the capacity to make an informed consent.

研究组 & 干预措施

Conventional Polyethylene versus metal head

Active Comparator

This is the more conventional group bearing surfaces

干预措施: Highly Cross Linked Polyethylene and oxidized zirconium femoral head (Device)

Conventional Polyethylene versus oxidized zirconium head

Experimental

This group uses the more conventional polyethylene against the newer head

干预措施: Highly Cross Linked Polyethylene and oxidized zirconium femoral head (Device)

Newer Cross linked Polyethylene metal head

Experimental

In this group we continued with the conventional polyethylene, but added in the new type of head (oxidized zirconium)

干预措施: Highly Cross Linked Polyethylene and oxidized zirconium femoral head (Device)

Newer Cross linked Polyethylene versus oxidized zirconium head

Experimental

In this group, we added both the new head and the new polyethylene

干预措施: Highly Cross Linked Polyethylene and oxidized zirconium femoral head (Device)

结局指标

主要结局

Wear rates of polyethylene over 10 years

时间窗: Over 10 years of wear rates

Linear and volumetric wear were measured in the most recent radiographs using a computer software package (Polyware Rev. 5; Draftware).

次要结局

  • Survivorship of implant combinations(over 10 years)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验

An Assessment of 4 Different Bearing Types in Hip... | 临床试验