跳至主要内容
临床试验/NCT06505642
NCT06505642
进行中(未招募)
不适用

Combined Needle-based Confocal Laser Endomicroscopy Cone-Beam Computed Tomography Navigation Bronchoscopy: a Proof of Principle Study

Academisch Medisch Centrum - Universiteit van Amsterdam (AMC-UvA)2 个研究点 分布在 1 个国家目标入组 25 人2024年10月8日

概览

阶段
不适用
干预措施
needle-based confocal laser endomicroscopy
疾病 / 适应症
Lung Neoplasm
发起方
Academisch Medisch Centrum - Universiteit van Amsterdam (AMC-UvA)
入组人数
25
试验地点
2
主要终点
CBCT navigation success and nCLE tool-in-lesion confirmation
状态
进行中(未招募)
最后更新
25天前

概览

简要总结

The goal of this proof of principle observational study is to investigate in patients with suspected peripheral pulmonary nodules. The main question it aims to answer is:

• What is the concordance between CBCT navigation success (tool-in-lesion on CBCT spin) and nCLE tool-in-lesion confirmation (tool-in-lesion nCLE criteria observed).

Participants scheduled to undergo a diagnostic conebeam navigation bronchoscopy will be included in the study. nCLE imaging at the tip of the TBNA needle will be added to the procedure for study purposes.

Two needle punctures of the pulmonary nodule will be followed by nCLE imaging directly followed by a tool-in-lesion CBCT spin in order to compare nCLE results with CBCT results.

详细描述

Lung cancer remains a significant problem in current society with one of the higher cancer related mortality rates. The increased use of chest computed tomography (CT) and the po-tential future lung cancer screening result in an increased detection of early-stage peripheral lung cancer. Bronchoscopies are often indicated to collect tissue for diagnosis and to aid treatment decision making. Diagnostic bronchoscopy for peripheral lung nodules remains challenging despite many tech-nological innovations. The procedure comprises three essential pillars needed for a diagnos-tic success: navigation to the lesion, tool-in-lesion confirmation and adequate tissue retrieval. Cone beam computed tomography navigation bronchoscopy (CBCT-NB) is a fairly new tech-nique that provides coarse navigation to the pulmonary lesion with real-time guidance using augmented fluoroscopy (AF). An initial CBCT scan allows for segmentation of the target le-sion and selecting the optimal pathway. Repeated CBCT scanning allows for confirmation that the target has been reached (navigation success) or if repositioning is needed. Although the technique is very promising, an often discussed disadvantage of CBCT is the inherent use of ionizing radiation, limited availability and challenges with small nodules lo-cated in the basal and posterior fields due to respiratory motion. Most procedures ask for multiple CBCT spins both for trajectory planning, tool adjustments and tool-in-lesion confir-mation. This, combined with extensive use of fluoroscopy is associated with radiation expo-sure for both patients and the investigation team. Additionally, CBCT-NB with AF provides information from a global perspective rather than a local perspective. In experienced centers, coarse navigation guidance seems of lesser concern and fine positioning and optimal tissue sampling are the biggest problems to be overcome. The persistently low diagnostic yield of navigation bronchoscopies can for the majority be attributed mispositioning of the tools in "the last centimeter". Therefore there is a need for complementary techniques providing real-time information for fine-tuning the needle position such as needle-based confocal laser en-domicroscopy (nCLE) also called the "smart needle". Confocal laser endomicroscopy (CLE) is a high-resolution microscopic technique that visual-izes individual cells in real-time at the tip of the biopsy needle, allowing for real-time micro-scopic feedback for fine tuning needle positioning and tool-in-lesion confirmation. Currently, it is unknown which (combination of) techniques are the most optimal (i.e., leading to a high di-agnostic yield and cost-effective). Therefore, research is needed to investigate the potential of new (combinations of) techniques. To date, there are no reports on the combination of CBCT-NB with nCLE. Objective: This study aims to investigate proof of principle of utilizing nCLE during CBCT-NB navigation bronchoscopy. A confirmatory CBCT spin is considered the gold standard for tool-in-lesion but is associated with additional radiation exposure. The aim is to investigate the concordance between CBCT navigation success (tool-in-lesion on CBCT spin) and nCLE tool-in-lesion confirmation (tool-in-lesion nCLE criteria observed). The investigators also hypothesize that nCLE could reduce or replace the need for additional confirmatory CBCT scans and limit fluoroscopy use. Study design: Investigator-initiated proof of principle medical device study Study population: Patients (18 years and older) with (suspected) pulmonary nodules with an indication for cone-beam computed tomography navigation bronchoscopy. Procedure: Cone beam computed tomography navigation bronchoscopy combined with needle-based confocal laser endomicroscopy. Main study parameters/endpoints: * CBCT-NB navigation success as either tool-in-lesion OR unsuccessful * nCLE tool-in-lesion confirmation, defined as tool-in-lesion nCLE criteria observed

注册库
clinicaltrials.gov
开始日期
2024年10月8日
结束日期
2026年6月1日
最后更新
25天前
研究类型
Interventional
研究设计
Single Group
性别
All

研究者

责任方
Principal Investigator
主要研究者

Prof. J.T. Annema, MD, PhD

Prof. dr. Jouke Annema

Academisch Medisch Centrum - Universiteit van Amsterdam (AMC-UvA)

入排标准

入选标准

  • 18 years or older
  • Suspected pulmonary nodule with an indication for CBCT-NB (decided by multidisciplinary tumour board)
  • Nodule must be solid or partially solid
  • Solid part of the nodule must be at least 8 mm
  • Largest dimension of the nodule on CT equal or less than 30 mm
  • Ability to understand and willingness to sign a written informed consent

排除标准

  • Inability or non-willingness to provide informed consent
  • Patients with an endobronchial visible lung tumor on bronchoscopic inspection
  • Patients in which the target lesion is within reach of the linear EBUS scope
  • Lung nodules that resolved at the time of index intraprocedural CBCT
  • Failure to comply with the study protocol
  • Patients with known allergy for fluorescein or risk factors for an allergic reaction
  • Pregnant or breastfeeding women
  • Patients with hemodynamic instability
  • Patients with refractory hypoxemia
  • Patients with a therapeutic anticoagulant that cannot be held for an appropriate in-terval before the procedure

研究组 & 干预措施

nCLE + CBCT-NB

Patients with a suspected malignant peripheral pulmonary nodule(s) referred for cone beam ct navigation bronchoscopy for tissue sampling.

干预措施: needle-based confocal laser endomicroscopy

结局指标

主要结局

CBCT navigation success and nCLE tool-in-lesion confirmation

时间窗: Intra-procedure

CBCT-NB navigation success: tool-in-lesion OR unsuccessful navigation nCLE tool-in-lesion confirmation: in-lesion nCLE criteria seen

次要结局

  • Interobserver agreement (IOA) and intraobserver reliability (IOR)(Intra-procedure)
  • Sensitivity, specificity and accuracy of post-procedure nCLE image assessment(Intra-procedure)
  • Technical feasibility(Intra-procedure)
  • Safety(Up to 7 days post procedure)
  • Sensitivity, specificity and accuracy of real-time nCLE imaging assessment(Intra-procedure)
  • Diagnostic yield(up to 6 months post procedure)
  • Diagnostic sensitivity for malignancy(up to 6 months post procedure)

研究点 (2)