跳至主要内容
临床试验/NCT07042698
NCT07042698尚未招募不适用

Evaluation of the Performance of Glomerular Filtration Rate Measurement Using CT Urography in Patients With Chronic Kidney Disease

Assistance Publique - Hôpitaux de Paris1 个研究点 分布在 1 个国家目标入组 70 人开始时间: 2025年7月15日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
尚未招募
入组人数
70
试验地点
1
主要终点
Assessment of the Reliability of GFR Measurement by 4-Phase CT Urography Compared to Iohexol Clearance

研究概览

简要总结

Glomerular filtration rate (GFR), which is the main biomarker used in clinical practice to assess kidney function, is usually estimated from the serum concentration of endogenous markers such as creatinine and/or cystatin C. GFR estimation equations all share the disadvantage of imperfect accuracy due to non-GFR-related determinants of creatinine and cystatin C. When knowing the exact GFR value is necessary for clinical decision-making, measurement by clearance of an exogenous tracer is required. Various tracers are available, some of which are radioactive tracers (99mTc-DTPA and 51Cr-EDTA), while others are iodinated contrast agents (iohexol, iothalamate). GFR measurement procedures are time-consuming and require significant human resources (4 to 5 hours, or even 24 hours for plasma clearances at very low GFR values).Urinary clearance methods may be inaccurate in cases of inadequate voiding. Plasma clearance results may be inaccurate in cases of increased (overestimation) or decreased (underestimation) extracellular volume, low GFR (unless late sampling is performed), or glomerular hyperfiltration. Measuring tracers requires either warm labs for measuring radioactive markers or labs with HPLC (High Performance Liquid Chromatography) chains for iohexol, which are part of an external quality assurance program. The complexity and/or length of GFR measurement procedures, their cost, and laboratory constraints explain why measured GFR is underused in routine clinical practice. There is a critical need to develop GFR measurement methods that are simpler to implement, reliable across the entire GFR spectrum, and widely available. We have demonstrated that it is possible to measure GFR using 4-phase CT urography performed as part of the care of living kidney donor candidates (healthy individuals with normal GFR). The examination takes 10 minutes, requires no biological sampling, and is not subject to potential inaccuracies due to sodium overload or poor bladder emptying.

详细描述

Objective

To assess whether GFR measurement using 4-phase CT urography is reliable in patients with GFR below 60 ml/min/1.73 m², as compared with iohexol clearance (reference method): - Unbiased (mean difference between CT-measured GFR and iohexol clearance not different from zero). - and accurate: at least 50% and 80% of GFR values measured by CT urography within 10% and 20% of biological clearance values for iohexol clearance.

Method: Single-center interventional study. After performing a 4-phase CT urography (or 3-phase CT scan, with the addition of a 4th phase for research purposes), performed for clinical indications as part of the patient's care, and using iohexol as a contrast agent, patients will undergo a biological measurement of iohexol clearance, based on serum and urine samples taken over 4 periods of 1 hour, between 3 and 7 hours after the CT scan. No iohexol will be reinjected to measure GFR. The CT scan images will be segmented by the investigator to determine the CT-measured GFR.

The inclusion criteria are: - Patients older than 18 years of age - Having given written consent to participate in the study. - Patient referred to the medical imaging department of the Henri Mondor University Hospital for a 3-phase or 4-phase abdominal CT scan. - With an estimated GFR according to CKD-EPIcreat2009 < 60 ml/min/1.73m² - Hospitalized or outpatient. - Affiliated with French national health insurance.

The exclusion criteria are: - Patients with hip implants, due to artifacts that make quantification of the contrast agent in the bladder unreliable. - Lack of health insurance - Patients under legal protection.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Patients older than 18 years of age
  • •Having given written consent to participate in the study
  • •Patient referred to the medical imaging department of the Henri Mondor University Hospital for a 3-phase or 4-phase abdominal CT scan
  • •With an estimated GFR according to CKD-EPIcreat2009 < 60 ml/min/1.73m²
  • •Hospitalized or outpatient
  • •Affiliated with French national health insurance

排除标准

  • •Patients with hip implants, due to artifacts that make quantification of the contrast agent in the bladder unreliable
  • •Lack of health insurance
  • •Patients under legal protection.

研究组 & 干预措施

GFR Measurement Using 4-Phase CT Urography and Comparison with Iohexol Clearance

Other

A study with one arm, adding experimental procedures to standard of care (a 4-phase CT urography and biological sampling) in order to evaluate the accuracy of GFR measurement by CT urography in patients with chronic kidney disease.

干预措施: Glomerular Filtration Rate measurement with iohexol clearance (Other)

结局指标

主要结局

Assessment of the Reliability of GFR Measurement by 4-Phase CT Urography Compared to Iohexol Clearance

时间窗: Day 1

To assess whether GFR measurement using 4-phase CT urography is reliable in patients with GFR below 60 ml/min/1.73 m², as compared with iohexol clearance (reference method): - Unbiased (mean difference between CT-measured GFR and iohexol clearance not different from zero). - and accurate: at least 50% and 80% of GFR values measured by CT urography within 10% and 20% of biological clearance values for iohexol clearance.

次要结局

  • Reliability Assessment of GFR Estimation Using Creatinine and/or Cystatin C Compared to Iohexol Clearance(Day 1)
  • Reliability of Hybrid GFR (Mean of CT-Measured and Creatinine/Cystatin C Estimated GFR)(Day 1)
  • Reliability of CT-Measured GFR Across Patient Subgroups Defined by Estimated GFR Ranges(Day 1)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验