MedPath

Axial Length Variability

Not Applicable
Completed
Conditions
Cataract Senile
Interventions
Other: Axial length variability
Registration Number
NCT04580550
Lead Sponsor
Vienna Institute for Research in Ocular Surgery
Brief Summary

The accuracy of IOL calculation relies on the one hand on axial length measurements and on the other hand on corneal and lens thickness measurements.

AL difference in pre and postoperative measurements may be caused by changes of lens parameters.

Aim of this study is to evaluate the magnitude of changes in pre and postoperative measurements of AL.

Detailed Description

This is a prospective observational, controlled and unmasked study that would include patients which undergo cataract presurgical examination, after patient signed written informed consent. For each patient only one eye will be included.

In total 50 eyes of 50 patients will be include. Due to missing previous data, the sample size is an approximation.

Prior to surgery, slit lamp examination and cataract grading (LOCS) is performed. Routine biometry is performed using the IOL Master 700 (Carl Zeiss Meditec AG, Jena, Germany) and Heidelberg Anterion (Heidelberg Engineering, Germany) for AL and lens measurement.

Additionally, evaluation of tilt and decentration will be performed using Purkinje meter device.

Follow-up examination will be performed three months after surgery and will contain: AL and lens measurement using the two ss-OCT biometery devices, lens evaluation (tilt and decentration of the IOL) using the Purkinje meter. Refractive outcome will be evaluated by determining best-corrected visual acuity and subjective refraction.

In women of childbearing age, a pregnancy test will be performed before inclusion into the study.

Main outcome variable:

• Extend of AL difference between pre- and postoperative measurements in both devices

Additional outcome variables:

* Agreement between the two ss-OCT devices in AL measurement

* Evaluation of lens parameter in AL differences between pre- and postoperative measurements

* Limit of agreement in lens tilt and decentration using two ss-OCT devices and Purkinje meter

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
50
Inclusion Criteria
  • Uneventful cataract surgery
  • Age 21 and older
  • Axial length 24.00 mm and bigger
  • CT Asphina 409 M lens implanted
Exclusion Criteria
  • Intra- or postoperative complication
  • Relevant other ophthalmic diseases that are likely to influence the measurement outcome (as: with severe corneal pathology, severe macular degeneration, severe diabetic retinopathy, dens cataract, PEX syndrome, previous ocular surgery or trauma)
  • Pregnancy

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
Axial length variabilityAxial length variabilityAim of this study is to evaluate the magnitude of changes in pre and postoperative measurements of AL.
Primary Outcome Measures
NameTimeMethod
Axial length variability3 months

Evaluation of changes in axial length pre and post cataract surgery using two ss-OCT biometers

Secondary Outcome Measures
NameTimeMethod
Lens tilt and decentration3 months

Evaluation of lens tilt and decantation using the Purkinje meter and two ss-OCT devices

Trial Locations

Locations (1)

Hanusch Hospital, Ophthalmology department

🇦🇹

Vienna, Austria