MedPath

Er,Cr:YSGG and Diode Lasers in the Treatment of Peri-implantitis

Not Applicable
Completed
Conditions
Peri-Implantitis
Registration Number
NCT04730687
Lead Sponsor
Yuzuncu Yıl University
Brief Summary

In this study, 940 nm diode laser and 2780 nm erbium, chromium doped: yttrium, scandium, gallium, garnet (Er, Cr: YSGG) laser were used in the non-surgical treatment of peri-implant diseases in addition to mechanical treatment. And the effects of dental lasers on clinical parameters and matrix metalloproteinase 9 (MMP-9) and tissue inhibitors of matrix metalloproteinases-1 (TIMP-1) levels in peri-implant crevicular fluid were evaluated.

Detailed Description

With the widespread use of dental implants, there is an increase in technical and biological complications. These complications are called peri-implant diseases in general terms. When peri-implant diseases are not treated, a process that progresses to the loss of the affected implant may develop, but there is still no accepted consensus on their treatment.When performing treatment procedures, it is recommended not only to remove inflamed tissues but also to decontaminate infected implant surfaces.Recently, with the development of laser technologies, the use of dental lasers in implant surface detoxification has come to the fore. Dental lasers attract increasing attention due to their anti-infective properties, easy handling and haemostatic effects against periodontal pathogens.Diode lasers attract attention with their safety when used directly on the implant surface, soft tissue penetration, antibacterial and biostimulating properties. They detoxify implant surfaces by killing pathogenic bacteria through photothermal effects and neutralizing bacterial endotoxins. Erbium lasers also show promising results in implant treatment due to their advantageous properties such as soft and hard tissue ablation and decontamination. Er, Cr: YSGG lasers have the ability to debride microstructured surfaces of dental implants without causing mechanical damage, thanks to their ability to work with water.Today, many researchers investigate the effectiveness of dental lasers in the treatment of peri-implant diseases, but it has not yet been proven whether they have an additional contribution. It is observed that studies mostly focus on clinical parameters. However, it is stated that periodontal probing and radiographs, which are used as common diagnostic methods, may give erroneous results. These methods refer only to pre-existing destruction rather than current disease activity. A model predicting the course of peri-implant disease has not yet been defined, but biomarkers may offer considerable potential for disease activity.Biomarkers are widely used in medicine to objectively determine disease state or responses to a therapeutic intervention. Gingival fluid (GCF) biomarkers have moderate diagnostic validity in periodontitis. It is stated that biomarkers in peri-implant groove fluid (PICF) also give promising results in terms of diagnosis and prognostic values. MMP-8 and MMP-9, the two main collagen degrading enzymes in GCF, are secreted from neutrophils during disease activation and are responsible for extracellular matrix degradation. TIMP-1, a major inhibitor of MMPs, has been reported to be released at high levels in inflamed gums.

In the literature review, it has been observed that there are quite a limited number of human clinical studies investigating the effect of dental lasers of different wavelengths on treatment results in the treatment of peri-implant disease at the clinical and molecular level. The aim of this study is to investigate the effects of 940 nm diode laser and 2780 nm Er, Cr: YSGG laser-assisted non-surgical mechanical treatment on clinical parameters and MMP-9 and TIMP-1 levels in PICF in individuals with peri-implant disease.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
50
Inclusion Criteria
  1. Inflammation in the peri-implant area,

    1. Probing depth ≥ 3 mm in one or more areas,
    2. Bleeding with probing with or without suppuration under light forces (0.25 N)
    3. Patients with bone loss [Patients with bone loss ≥ 2mm identified as peri-implantitis],
  2. There is no evidence of occlusal overload,

  3. Implant-supported fixed prosthesis that has been in use for at least 6 months in the mouth and does not interfere with the evaluation of clinical parameters.

Exclusion Criteria
  1. Smoking
  2. Having a systemic disease that may affect the treatment results such as uncontrolled diabetes, metabolic bone diseases, hematological disorders, radiotherapy in the head and neck region, kidney disease,
  3. Being in pregnancy or breastfeeding period,
  4. Using antibiotics and / or non-steroidal anti-inflammatory drugs in the last 3 months,
  5. Steroid and bisphosphonate use,
  6. To have any dental treatment in the last 3 months,
  7. Requiring surgical techniques in the treatment of peri-implant disease.

Study & Design

Study Type
INTERVENTIONAL
Study Design
CROSSOVER
Primary Outcome Measures
NameTimeMethod
Plaque index score (0-3)6 months

Plaque index was measured from the 4 surfaces of each implant. The plaque index score of each implant was calculated with Silness-Loe plaque index by dividing the total value by 4.

0:absence of microbial plaque

1. Thin film of microbial plaque along the free peri-implant margin

2. moderate accumulation with plaque in the sulcus

3. large amount of plaque in sulcus or pocket along the free peri-implant margin

Probing depth (mm)6 months

Probing depth (PD) (distance from peri-implant margin to peri-implant pocket base) was measured with a plastic probe (UNC 12 Colorvue probe, Hu-Friedy, Chicago, USA) in 4 regions (mesial, buccal, distal, lingual / palatinal) of each implant and recorded as mm.

Matrix Metalloproteinase-9 (MMP-9) level (ng/mL)6 months

Samples were collected using specially prepared paper strips (PerioPaper, Oraflow, NY, USA). The strips were stored in 1.5 mL sterile eppendorf tubes with 500μl phosphate-based saline (PBS) at pH 7.4. and -40 ° C. PICF samples were collected again from the same site of the same implant at 6 months following the treatments. When the targeted number is reached, in the investigation of MMP-9 levels in PICF, enzyme-linked immunosorbent assay (ELISA) is carried out in line with the recommendations of the manufacturer (Human Matrix Metalloproteinase-9 ELISA Kit, Bioassay Technology Laboratory, Shanghai, China). Absorbance values were read with a 450 nm wavelength ELISA reader (µQuantTM ELISA Microplate Reader, BioTek® Instruments, Inc., Vermont, USA).

Gingival index score (0-3)6 months

The gingival index was measured from the 4 surfaces of each implant. The gingival index score of each implant was calculated with Silness-Loe gingival indeks by dividing the total value by 4.

0:Normal gingiva

1. Mild inflammation: slight change in color, slight oedema, no bleeding on probing

2. Moderate inflammation: redness,oedema and glazing, bleeding on probing

3. Severe inflammation: marked redness and oedema, ulceration, tendency to spontaneous bleeding

Bleeding on probing (percentage)6 months

Bleeding on probing was measured by Ainamo and Bay's gingival bleeding index from 4 surfaces of each implant. If there is bleeding after probing, it is recorded as +, if there is no bleeding it is recorded as _. Gingival bleeding index is calculated as a percentage of affected sites.

Tissue Inhibitors of Metalloproteinase-1 (TIMP-1) level (pg/mL)6 months

Samples were collected using specially prepared paper strips (PerioPaper, Oraflow, NY, USA). The strips were stored in 1.5 mL sterile eppendorf tubes with 500μl phosphate-based saline (PBS) at pH 7.4. and -40 ° C. PICF samples were collected again from the same site of the same implant at 6 months following the treatments. When the targeted number is reached, in the investigation of TIMP-1 levels in PICF, enzyme-linked immunosorbent assay (ELISA) is carried out in line with the recommendations of the manufacturer (Human Tissue Inhibitors of Metalloproteinase-1 ELISA Kit, Bioassay Technology Laboratory, Shanghai, China). Absorbance values were read with a 450 nm wavelength ELISA reader (µQuantTM ELISA Microplate Reader, BioTek® Instruments, Inc., Vermont, USA).

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Nazli Zeynep Alpaslan Yayli

🇹🇷

Van, Turkey

Nazli Zeynep Alpaslan Yayli
🇹🇷Van, Turkey

MedPath

Empowering clinical research with data-driven insights and AI-powered tools.

© 2025 MedPath, Inc. All rights reserved.