MedPath

Comparison of a New EDOF-IOL With a Standard-EDOF-IOL

Not Applicable
Conditions
Cataract
Interventions
Procedure: Cataract surgery with Artis Active IOLs
Procedure: Cataract surgery with AT Lara IOLs
Registration Number
NCT03921762
Lead Sponsor
Prim. Prof. Dr. Oliver Findl, MBA
Brief Summary

Comparison of the new extended depth of focus (EDOF) intraocular lens (IOL) ARTIS ACTIVE, which is designed as a twinset of IOLs, with the standard EDOF IOL AT Lara .

Detailed Description

Spectacle independence is a central aim in modern cataract surgery. Although bilateral monofocal IOL implantation, aiming for emmetropia or low myopia, leads to high levels of patient satisfaction in distance vision, spectacle dependence for reading and other near vision tasks is the usual result.

The option commonly used to achieve spectacle independence are multifocal intraocular lenses (IOLs). Multifocal IOLs either use a refractive or diffractive design or a combination of both or segmented asymmetric optics. The principal of the refractive design is based on changing the route of light rays by thickness, curvature and optical density of the lens. The principal of diffractive design is based on scattering of light rays when passing an edge in the material of the lens. Usually, the characteristic diffractive ring patterns are incorporated on the posterior surface of an IOL, whereas the anterior lens surface remains purely refractive. One potentially negative aspect of multifocal refractive IOLs is pupil size dependence, another is loss of light energy to higher order diffraction which is not useful for the patient. In clinical studies, diffractive lenses resulted in a better outcome in terms of optical quality, better contrast sensitivity, and less photic phenomena (dysphotopsia such as halos and glare) compared to refractive lenses.

Until recently multifocal lenses were typically bifocal with a focus assigned to near and a focus assigned to far vision. However, the intermediate working distance is poorly covered by the bifocal design. Since objects commonly viewed in this distance include computer displays and tablets, the intermediate distance has become a crucial part in daily life. Variations in the addition of power chosen for near vision provided some intermediate visual acuity, but still suboptimal. Therefore, a new concept of multifocality has been introduced, the trifocal lens. Trifocal IOLs provide three focal distances: far, intermediate, and near. This ideally results in even less spectacle dependence, including for computer work. However, one potential disadvantage of trifocal IOLs is slightly poorer near vision compared to bifocal IOLs with need for reading glasses for prolonged fine near work and loss of contrast sensitivity in the intermediate distance.

A better intermediate performance concerning contrast vision compared to trifocal IOLs can be reached using enhanced depth of focus (EDOF) lenses. These IOLs have an extended far focus area which reaches to the intermediate distance, providing high-quality vision over a continuous range of focus, rather than distinct foci with blur in between.

To provide similar outcomes to trifocal IOLs, mix-and-match of additions ("blended vision") is another option, in which additions of multifocal IOLs between both eyes differ. The idea behind it is to improve the contrast in the intermediate distance compared to trifocal IOLs. The combination of +1.75D/ +4D10 and +1.5D/ +3D11 successfully achieved a regular defocus curve, but patient's subjective binocular comfort was not determined. To preserve the binocular balance between the eyes, a difference in addition of 0.5D was proposed and the combination of +2.5D/ +3D showed similar results as trifocal IOLs, except in the intermediate range of -1D and -1.5D.

Therefore, it would be necessary to provide an IOL with a continuum of good visual acuity from distance to 40 cm using binocularity to preserve binocular balance between the eyes. Hence, the primary objective of this study is to compare a new designed twinset of EDOF IOLs, ARTIS ACTIVE (Artis Active Mid and Artis Active Plus), with the standard EDOF IOL AT Lara in binocular visual acuity at 40 cm. Secondary objective is to compare binocular contrast sensitivity (with and without glare), binocular defocus curves with distance correction, monocular and binocular halos, and reading speed between the two IOLs.

Recruitment & Eligibility

Status
UNKNOWN
Sex
All
Target Recruitment
28
Inclusion Criteria
  • > 50 years old
  • Bilateral age-related cataract
  • Qualify for bilateral implantation within 1 month
  • No previous refractive or ocular surgery
  • Available IOL dioptre range: 18 to 27D
  • Expected postoperative astigmatism ≤ 0.75D
Exclusion Criteria
  • Pupil > 4 mm
  • Occupation requiring night-time driving or any occupation incompatible with multifocality
  • Acute or chronic disease or illness that would increase risk or confound study results [e.g. diabetes mellitus (with retinopathy), immunocompromised, glaucoma, epiretinal membrane, cornea guttata, etc....] found to be relevant by the investigators
  • Amblyopia, strabismus
  • Extremely shallow anterior chamber
  • Capsule or zonular abnormalities that may affect postoperative centration or tilt of the lens (e.g. pseudoexfoliation syndrome, uveitis, Marfan's syndrome)
  • Pupil abnormalities (non-reactive, tonic pupils, abnormally shaped pupils or pupils that do not dilate under mesopic/ scotopic conditions)
  • Instability to place the intraocular lens safely at the location planned
  • Pregnancy (pregnancy test will be taken pre-operatively in women of reproductive age)

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Artis Active IOLCataract surgery with Artis Active IOLsArtis Active IOLs (Artis Active Mid, Artis Active Plus) will be implanted in patients eyes during cataract surgery
AT Lara IOLCataract surgery with AT Lara IOLsAT Lara IOLs will be implanted in patients eyes during cataract surgery
Primary Outcome Measures
NameTimeMethod
Assessment of binocular near visual acuity12 months

Binocular near visual acuity in logMar will be measured at 40 cm distance using an ETDRS visual acuity chart

Secondary Outcome Measures
NameTimeMethod
Assessment of halos12 months

Extent of halos will be measured and analysed using the Aston halometer

Assessment of reading speed12 months

Patients reading speed will be measured using the Salzburg Reading Desk

Assessment of binocular far and intermediate visual acuity12 months

Binocular far and intermediate visual acuity in logMar will be measured at 4 metre and 70 cm distance using an ETDRS visual acuity chart

Assessment of binocular contrast sensitivity12 months

Binocular contrast sensitivity will be measured using the Optec Vision tester under mesopic and photopic conditions

Trial Locations

Locations (1)

Vienna Institute for Research in Ocular Surgery (VIROS)

🇦🇹

Vienna, Austria

© Copyright 2025. All Rights Reserved by MedPath