The Effect of Phototherapy Treatment on Oxygen Saturation Measurement in Newborns

Completed
Conditions
Hyperbilirubinemia, Neonatal Indirect
Registration Number
NCT04494217
Lead Sponsor
Hacettepe University
Brief Summary

This will be a prospective clinical study conducted with the approval of the Clinical Research Ethics Committee.

The influence of phototherapy lights on the accuracy of pulse oximetry will be investigated.

Detailed Description

Each patient's oxygen saturation will be measured non-invasively via a nondisposable polyethylene neonatal probe taped to the infant's palm, toe, or dorsum of the foot. The probe will be connected to an Massimo Rad97 pulse oximeter that is standardized at the factory. It runs through an automatic systems check when turned on and needs no further calibration before being used. The oxygen saturation measurements will be considered valid when there will be a normal plethysmographic waveform, a fullscale signal strength bar, and a stable heart rate closely approximating an independent electrocardiographic (ECG) pulse rate. The pulse oximeter works by using the technology of plethsmography which allows the detection of an arterial pulse) with oximetry (which measures oxygen saturation at specific wavelengths). The pulse oximeter will be placed on each infant as already described. After a stable pulse oximeter reading was obtained, the value will be recorded ("before") and then the probe will be covered with a standard disposable diaper, shiny side up. When the reading stabilized, the value will be recorded ("during") and then the diaper will be removed.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
50
Inclusion Criteria
  • newborn babies (0-28 days)
  • to be treated in the Hacettepe University Children's Hospital Neonatal Intensive Care Unit
  • receiving phototherapy treatment
Read More
Exclusion Criteria
  • Newborn babies with any diseases that affect oxygen saturation including congenital heart disease, chromosomal disease, inborn error of metabolism, anemia, circulatory disorder, hypovolemia or hydrops fetalis
Read More

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Primary Outcome Measures
NameTimeMethod
Percent Oxygen Saturation Before and During Covering Oximeter ProbeThe two data (''before'' and ''during'') will be recorded consecutively for each infant, when the reading stabilize. All measurements will be completed wiithin 6 months according to the study protocol calendar.

The two data points (percent oxygen saturation before and during covering of oximeter probe) for each patient will be compared.

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Hacettepe University

🇹🇷

Ankara, Turkey