Skip to main content
Clinical Trials/NCT06493929
NCT06493929
Not yet recruiting
Not Applicable

Mechanical Power As a Predictor for Weaning in Chronic Obstructive Pulmonary Disease Patients :Prospective Cohort Study.

Assiut University1 site in 1 country84 target enrollmentDecember 1, 2024

Overview

Phase
Not Applicable
Intervention
Not specified
Conditions
Mechanical Power
Sponsor
Assiut University
Enrollment
84
Locations
1
Primary Endpoint
1. Evaluation the efficacy of MP as a predictor of weaning for COPD patients.
Status
Not yet recruiting
Last Updated
last year

Overview

Brief Summary

The primary objective is to evaluate the mechanical power as a predictor of weaning of mechanical ventilation in COPD patients hospitalized in the respiratory intensive care unit of Assiut University Hospital The secondary objective is to compare between mechanical power and diaphragmatic excursion (DE) assessed by ultrasound as a predictor of weaning in these patients. Also, to investigate the association between MP and DE and mortality in these patients

Detailed Description

Acute exacerbation of chronic obstructive pulmonary disease (AECOPD), a public health problem that is characterized by persistent airflow limitation ,it develops when there is a significant exposure of irritants causing an inflammatory response in the lungs, it is a common cause of respiratory failure which require hospital admission that is associated with increased medical costs. The World Health Organization reported that COPD was the fifth most common disease globally in 2020, with a prevalence of 7.8-19.7% in adults. Approximately, 60% of patients with COPD admitted with hypercapnic respiratory failure. Acute exacerbations of chronic obstructive pulmonary disease (COPD) is characterized by acute worsening of respiratory symptoms associated with the development of severe airflow limitation, gas trapping, dynamic hyperinflation and intrinsic positive end-expiratory pressure (PEEPi). In the most severe cases, these exacerbations may cause acute respiratory failure, which may require mechanical ventilation. The process of weaning from mechanical ventilation remains one of the most critical challenges in patients underwent mechanical ventilation in the intensive care unit (ICU). The multidisciplinary team must study the optimal time for weaning from the mechanical ventilator as premature weaning may lead to weaning failure and thus increase the risk of hospital acquired infections, costs of care, length of ICU stay, Morbidity and Mortality. Current guidelines recommend several indices applied at the bedside to predict successful weaning from mechanical ventilation. A spontaneous breathing trial (SBT) is an appropriate way to prepare the patient for extubation; however, even after successful SBT, failure rates and subsequent reintubation can exceed 20% in the highest-risk patient. Mechanical power (MP) is the energy delivered by the ventilator to the entire respiratory system per time unit and combines all factors affecting the energy load of the respiratory system, including pressure, tidal volume, flow rate and respiratory rate. MP is primarily calculated as the product of the applied airway pressure and minute ventilation and can be used as an estimate of the workload exerted on the respiratory muscles during spontaneous breathing. MP is a major determinant to ensure adequate gas exchange in the body and a key factor in assessing the ability of a patient to successfully wean from mechanical ventilation. Therefore, a larger scale clinical study is needed to further verify the relationship between MP and weaning outcomes in all critically ill mechanically ventilated patients.

Registry
clinicaltrials.gov
Start Date
December 1, 2024
End Date
August 1, 2026
Last Updated
last year
Study Type
Observational
Sex
All

Investigators

Responsible Party
Principal Investigator
Principal Investigator

Mohamed Mamdouh Moustafa

Assistant Lecturer

Assiut University

Eligibility Criteria

Inclusion Criteria

  • All COPD mechanically ventilated patients admitted to respiratory intensive care unit and eligible for weaning according to European respiratory society 2016 (5).

Exclusion Criteria

  • Patients with associated lung pathology that may alter lung mechanics (Bronchiectasis, interstitial lung diseases, lung scarring) will be excluded from the study.
  • Tracheostomized patients.

Outcomes

Primary Outcomes

1. Evaluation the efficacy of MP as a predictor of weaning for COPD patients.

Time Frame: 2 years

Evaluation the efficacy of MP as a predictor of weaning for COPD patients.

Secondary Outcomes

  • 2-MP and duration of hospital stay and ICU stay.(2 years)
  • 1-MP as a predictor of patient's mortality.(2 years)
  • 4-Correlation analysis between mechanical power and other parameters of weaning: Respiratory rate, Rapid shallow breathing index, Heart Rate and Expiratory Tidal volume in evaluation of prognosis in COPD patients.(2 years)
  • 3-MP and ventilator induced lung injury.(2 years)

Study Sites (1)

Loading locations...

Similar Trials