Minimally Invasive Closed Reduction and Internal Fixation With Fully Threaded Headless Cannulated Compression Screws for Repair of Distal Radius Fracture: Study Protocol for a Randomized Controlled Trial

Shenyang Medical College0 个研究点目标入组 60 人开始时间: 2016年6月1日最近更新:
适应症

试验速览

阶段
不适用
发起方
入组人数
60
主要终点
change of X-ray findings

研究概览

简要总结

The purpose of this study is to confirm that minimally invasive closed reduction and internal fixation with fully threaded headless cannulated compression screws for distal radius fracture repair has advantages over conventional open reduction internal fixation with titanium plates, providing superior fragment stability and allowing for early rehabilitation exercise of the wrist joint, which improves recovery of function. Also to show that minimally invasive closed reduction and internal fixation with fully threaded headless cannulated compression screws is the more suitable surgical method for repair of distal radius fracture.

详细描述

Distal radius fracture is defined as a fracture within 3 cm of the distal articular surface. When radius fracture and ulnar styloid process fracture occur together, internal fixation is generally not pursued; however, adverse events may occur after reduction with external fixation, including unstable fracture fragments, malalignment, and loss of radial inclination and ulnar deviation, leading to wrist function impairment.

The commonly used treatment methods for distal radius fracture include internal fixation with steel plate, internal fixation with Kirschner wire, and external fixation. Open reduction and internal fixation (ORIF) has disadvantages. For example, the pronator teres is incised in palmar ORIF and in situ suturing of the muscle is not possible in most patients after implantation of the titanium plate. Even when suturing is possible, the strength of the pronator teres will decrease after surgery, and a second surgery is needed to remove the titanium plate. Dorsal ORIF is also disadvantageous because more tendons and thin soft tissue may be encountered during surgery. In addition, tendon sheath injury is inevitable, leading to myotenositis, tendon adhesion, and even tendon rupture. Thus, internal fixators should be taken out as early as possible. Satisfactory wrist function outcomes have been achieved with external fixators, in particular with dynamic external fixators. However, although external fixation has good fixing effects, it provides poor lateral stability, resulting in injury to the superficial branch of the radial nerve, screw channel infection, screw channel fracture, screw loosening, and even Sudeck's atrophy. Internal fixation with Kirschner wire generates minimal surgical trauma, but this technique does not provide sufficient strength for fixation and is therefore rarely used at present. There is an urgent need to develop a more stable fixation method for distal radius fracture. Minimally invasive surgery avoids the tissue damage and impairment of physiological function caused by open surgery because of its precise location techniques. Brachial plexus anesthesia allows surgeons to avoid large incisions and excessive bleeding. There are no palmar or dorsal incisions in minimally invasive surgery for distal radius fractures, so the structures surrounding the wrist joint are not iatrogenically damaged, which theoretically improves wrist function recovery.

During C-arm fluoroscopy-assisted minimally invasive closed reduction, either no surgical incision or an incision only 0.5 cm in length is made at the wrist joint; the fracture fragments are reduced with fully threaded headless cannulated compression screws. Repair stability is assessed with the C-arm fluoroscopic X-ray system. This method is theoretically feasible for distal radius fractures. The fracture fragments are fixed with fully threaded, cannulated, variable-pitch, headless compression screws, which can increase fragment stability. Therefore, the investigators hypothesize that C-arm fluoroscopy-assisted minimally invasive closed reduction will fix distal radius fractures and allow patients to perform wrist function exercises as early as possible.

Our previous studies have confirmed that minimally invasive closed reduction and internal fixation with fully threaded headless cannulated compression screws has precise therapeutic effects for distal radius fractures. This method can improve wrist function, and has therapeutic effects similar to those of conventional open reduction and internal fixation with titanium plates. The results of these previous studies are shown in Table 1. However, it is not clear whether minimally invasive closed reduction and internal fixation with fully threaded headless cannulated compression screws has advantages over conventional open reduction and internal fixation with titanium plates for distal radius fracture repair.

In this study, the investigators hypothesized that minimally invasive closed reduction and internal fixation with fully threaded headless cannulated compression screws provides better stability than conventional methods, and can effectively promote the early recovery of wrist function. Under conditions of no cutting of fracture fragments, no blood supply compromise in the fracture fragments, and no destruction of the local microenvironment, and with C-arm fluoroscopy assistance, the investigators will perform minimally invasive closed reduction, pressurizing the fracture fragments with fully threaded headless cannulated compression screws, and will investigate whether this method of distal radius fracture repair provides satisfactory stability and allows early wrist function recovery.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Double (Participant, Investigator)

入排标准

年龄范围
55 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Age 55 years or older, either sex
  • A history of known trauma
  • Presence of wrist joint pain and limitation of motion after trauma
  • Fracture occurring 2.0-3.0 cm proximal to the articular surface, confirmed with imaging findings
  • Unstable distal radius fracture
  • Dorsal displacement of fracture fragment
  • Fracture involving the wrist joint, but no more than two fracture fragments involving the wrist joint

排除标准

  • Acute fracture of several other regions, including the ulnar styloid process
  • Open fracture
  • Mental disorder
  • Occurrence of fracture more than 21 days before presentation
  • Severe heart, lung, liver, or kidney function disorder
  • Severe local infection after fracture
  • Refusal to sign informed consent form
  • Poor compliance, or upon the request of the sponsor for safety reasons
  • If participation in the trial would be a potential hazard to patient's health

结局指标

主要结局

change of X-ray findings

时间窗: Baseline and week 3, week 6, week 12, week 24 after surgery

X-ray findings to evaluate fracture healing

次要结局

  • change of healing of fracture(week 3, week 6, week 12, week 24 after surgery)
  • change of Visual Analogue Scale(VAS) score(week 3, week 6, week 12, week 24 after surgery)
  • change of CT findings(Baseline and week 3, week 6, week 12, week 24 after surgery)
  • change of patient-rated wrist evaluation score results(week 3, week 6, week 12, week 24 after surgery)