MedPath

Mini-C-Arm for Distal Radius Fractures in Adults

Not Applicable
Completed
Conditions
Distal Radius Fracture
Interventions
Other: Mini-c-arm
Registration Number
NCT03396965
Lead Sponsor
University of Cincinnati
Brief Summary

Determine efficacy of the use of mini-c-arm fluoroscopy for the closed reduction of isolated distal radius fractures in adult patients in the emergency department setting.

Detailed Description

Not available

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
63
Inclusion Criteria
  • Closed distal radius fracture requiring reduction
Exclusion Criteria
  • Open, other ipsilateral upper extremity fractures, pregnant, incarcerated, less than 18 yo

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
Mini-c-armMini-c-armFluoroscopically aided reductions
Primary Outcome Measures
NameTimeMethod
Reduction qualityImmediately post reduction

Fracture alignment measured on post-reduction radiographs

Secondary Outcome Measures
NameTimeMethod