跳至主要内容
临床试验/NCT04171414
NCT04171414已完成3 期

A Phase III, Open-label, Single-arm, Multiple-dose Study to Evaluate Usability of Subcutaneous Auto-injector of CT-P17 in Patients With Moderate to Severe Active Rheumatoid Arthritis

Celltrion1 个研究点 分布在 1 个国家目标入组 62 人开始时间: 2019年9月9日最近更新:
适应症

试验速览

阶段
3 期
状态
已完成
发起方
Celltrion
入组人数
62
试验地点
1
主要终点
The Usability as Assessed by Patients Rating Using PRE- and POST-Self-Injection Assessment Questionnaire (SIAQ) at Week 4

研究概览

简要总结

Clinical trial to evaluate Usability of Subcutaneous Auto-injector of CT-P17 in Patients With Active Rheumatoid Arthritis

详细描述

CT-P17, containing the active ingredient adalimumab, is a recombinant humanized monoclonal antibody that is being developed as a similar biological medicinal product to Humira. The purpose of this study is to evaluate usability of subcutaneous auto-injector of CT-P17 in patients with moderate to severe rheumatoid arthritis.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 70 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Male or female patient aged 18 to 70 years, inclusive.
  • Patient must be able and willing to self-administer subcutaneous (SC) injections via auto injector (AI).

排除标准

  • Patient who has previously received investigational or licensed product; biologic or targeted synthetic disease-modifying antirheumatic drugs for the treatment of rheumatoid arthritis and/or a tumor necrosis factor (TNF) α inhibitor for any purposes.
  • Patient who has allergies to any of the excipients of study drug or any other murine and human proteins, or patient with a hypersensitivity to immunoglobulin products.

结局指标

主要结局

The Usability as Assessed by Patients Rating Using PRE- and POST-Self-Injection Assessment Questionnaire (SIAQ) at Week 4

时间窗: Week 4

The usability of CT-P17 Auto Injector is measured by participant using PRE- and POST-Self-injection Assessment Questionnaire (SIAQ) modules. The PRE-SIAQ module is a 7-item questionnaire and the POST-SIAQ module is a 27-item questionnaire that assesses feelings about injections, self-image, self-confidence (regarding self-administration), pain and skin reactions before after injection. Participants rated each item of the SIAQ on a 5-point (or 6-point) semantic Likert-type scal. (each item graded on a 5-point scale). \[Scores were transformed to Rate between 0 (worst) to 10 (best)\]

次要结局

  • Observer's Rating of Successful Self-injection Using Self-injection Assessment Checklist at Weeks 0, 2, 4, and 24(Week 0,2,4,24)
  • Mean for Actual Values and Change From Baseline in DAS28 (CRP and ESR)(Week 8,16,24)
  • Patient's Rating of PRE- and POST-SIAQ at Weeks 0, 2, and 24(Week 24)

研究者

发起方
Celltrion
申办方类型
Industry
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验