Study to Determine the Safety and Feasibility of Utilizing the CD Leycom Pressure/Conductance Catheter to Determine Optimal LV Pacing Site

Lancaster General Hospital2 个研究点 分布在 1 个国家开始时间: 2012年4月最近更新:
适应症

试验速览

阶段
1 期
状态
撤回
试验地点
2
主要终点
Feasibility

研究概览

简要总结

It is hypothesized that it is both safe and feasible to use an interventional approach to LV lead placement (placing the LV lead guided by acute hemodynamic measurements), and that the LV lead can be placed in a position that is superior to the initial empiric lateral wall LV lead location in less than 30 minutes without significant risk to patients. The time from RV capture to LV activation correlates with the optimal pacing site based on stroke volume & dP/dt measurements.

详细描述

Background

Cardiac synchronization therapy (CRT) is recognized as effective adjunctive therapy for heart failure; however, up to 40% of patients who undergo CRT device placement do not have a favorable response to therapy and are labeled non-responders. The lateral wall of the left ventricle (LV) is generally regarded as the optimal site for LV lead placement and some non-responders with LV leads not on the lateral wall can be converted to responders by repositioning the LV lead to the lateral wall. However, recent studies indicate that in some patients LV lead placement at a site other than the lateral wall may result in a better response to CRT. In such circumstances, empiric lateral wall lead positioning/repositioning may expose patients to the risks of another invasive procedure (including an increased risk of infection); in the case of lead repositioning to improve response to CRT the additional risk is doubled, as there is no certainty that the new position will be superior to the old.

Several investigators have used the acute hemodynamic response to biventricular pacing to determine the optimal LV lead position. To make these measurements some groups used a Millar pigtail catheter (Millar Instruments, Houston, Texas) while other groups used real-time pressure volume loops with a combined pressure-conductance catheter (CD Leycom, Zoetermeer, the Netherlands). One criticism of this method is that acute hemodynamic measurements may not correlate to long term response. However, Delnoy et al demonstrated that acute improvements in LV function as measured by pressure-volume loops during implantation corresponded to clinical and echocardiographic improvement during follow-up. In addition, Duckett et al demonstrated that the acute dP/dt response to LV pacing is useful for predicting which patients are likely to remodel in response to CRT, for both dilated and ischemic cardiomyopathy.

Despite these observations, few practitioners routinely utilize acute hemodynamic measurements for LV lead placement at the time of device implantation. Many practitioners believe targeted LV lead placement is impractical due to the time required to determine hemodynamic response to CRT and reposition the LV lead, and that venous anatomy, phrenic nerve pacing, and high pacing thresholds severely limit options for LV lead placement.

Study Hypothesis

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • 未提供

排除标准

  • 未提供

结局指标

主要结局

Feasibility

时间窗: 30 Minutes

Feasibility of measuring dP/dt in a maximum of 3 veins within 30 minutes.

Procedure time

时间窗: 2 Hours

Additional procedure time for pressure measures.

Radiation exposure

时间窗: 2 Hours

During procedure as measured with Gafchromic film.

Death

时间窗: 1 Month

From procedure.