Comparative Study of Bispectral Index (BIS) Values Obtained From Standard Frontal Position and Alternative Infra-orbital Position During Total Intravenous Anaesthesia (TIVA).

Universiti Sains Malaysia1 个研究点 分布在 1 个国家目标入组 71 人开始时间: 2020年6月30日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
71
试验地点
1
主要终点
agreement between frontal BIS vs infraorbital BIS

研究概览

简要总结

A study to find agreement of the infraorbtal BIS placement as compared to standard frotal placement

详细描述

2.1 Study Design This was a prospective, cross-sectional study conducted in single centre, University Hospital. The study protocol was reviewed and granted approval for implementation by the institution Human Research and Ethics Committee (study protocol code: USM/JEPeM/20060307).

2.2 Study Population We recruited 71 patients who were eligible to be enrolled in this study from November 2020 to October 2021. The inclusion criteria were consented adults between the age of 18 and 60 years old, BMI > 18 and <30 kg/m2 and ASA physical status I or II underwent general elective surgery under general anaesthesia. We excluded patients who were going for neurosurgery, maxillofacial or facial surgical procedures because the operation site may interfere with the BIS sensors placement. Patients with a history of disabling central nervous or cerebrovascular disease, those on psychiatric medication or central nervous system active drugs, and those who had undergone neurosurgical procedure were also excluded. The patient who had interruption of BIS monitoring of any BIS sensor location at any time frame will be withdrawn from the study.

The baseline demographic data of patients were extracted from their medical chart. Demographic data include their age, gender, BMI, ASA physical status and type of surgery.

2.3 Study Method Before induction of anaesthesia, we applied two BIS sensors on each patient at different location (frontal & infra-orbital) and connected two different BIS monitor. Frontal sensors were applied with circle 1 at the centre of forehead, circle 2 2.8cm lateral to circle 1, circle 3 on the corner of the eye and circle 4 in between circle 2 and circle 3 (Picture 1(A)). Infra-orbital sensors were applied with circle 1 across the nose bridge, circle 2 adjacent to circle 1, circle 3 medial from the frontally placed third electrode and circle 4 in between circle 2 and 3 (Picture 1 (B)). Anaesthesia was induced with TCI remifentanil at initial target concentration at 2ng/ml up to 4ng/ml followed with TCI propofol at initial target concentration at 4mcg/ml then titrated upwards to loss of consciousness and intravenous (IV) rocuronium 1.0 mg/kg for muscle relaxant and endotracheal intubation. Anaesthesia was maintained with propofol infusion at target plasma concentration of 3-6mcg/ml and remifentanil 1-8ng/ml; Intra-operative analgesia included IV paracetamol 1g, IV parecoxib 40mg and IV morphine 0.05-0.1mg/kg. At the end of surgery, patients were reversed with IV neostigmine 0.05 mg/kg and atropine 0.02mg/kg. BIS values from each BIS monitor during awake, at loss of consciousness (LOC), after intubation, after the start of surgical incision, every 30 minutes during the intraoperative period (maintenance), after cessation of TCI propofol at which the plasma concentration of propofol is 1.5mcg/ml (emergence) and at extubation were recorded. The frontal BIS was used to guide the depth of anaesthesia, with deep (BIS < 45), moderate (BIS 45 to 60) and mild hypnosis (BIS >60).

2.4 Sample Size In order to determine the Kappa agreement for Pearson's correlation between BIS values obtained from frontal versus the infra-orbital sensor position, using t-test, the sample size would be determined with parameter of effect 0.3, an alpha of 0.05 and a power of 80%. The sample size required was 64 patients and with the estimation of 10% drop-out rate, the total number would be 71 patients.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Crossover
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 60 Years(Adult)
性别
All
接受健康志愿者
是

入选标准

  • •were consented adults between the age of 18 and 60 years old, BMI > 18 and <30 kg/m2 and ASA physical status I or II underwent general elective surgery under general anaesthesia. We excluded patients who were going for neurosurgery, maxillofacial or facial surgical procedures because the operation site may interfere with the BIS sensors placement. Patients with a history of disabling central nervous or cerebrovascular disease, those on psychiatric medication or central nervous system active drugs, and those who had undergone neurosurgical procedure were also excluded. The patient who had interruption of BIS monitoring of any BIS sensor location at any time frame will be withdrawn from the study.

排除标准

  • 未提供

研究组 & 干预措施

frontal BIS

Placebo Comparator

frontal BIS is a standard position

干预措施: Bispectral index (Device)

infraorbital BIS

Active Comparator

Infraorbital BIS is a comparator to find agreement with standard location

干预措施: Bispectral index (Device)

结局指标

主要结局

agreement between frontal BIS vs infraorbital BIS

时间窗: intraoperative

measurements of BIS values on both placement

次要结局

  • correlation between frontal BIS vs infraorbital BIS(intraoperative)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Mohamad Hasyizan Hassan

Senior Lecturer and Neuroanaesthesiologist

Universiti Sains Malaysia