跳至主要内容
临床试验/NCT05150054
NCT05150054已完成不适用

Magnetocardiography as a Noninvasive Diagnostic Strategy for Suspected Coronary Microvascular Dysfunction

Genetesis Inc.4 个研究点 分布在 1 个国家目标入组 93 人开始时间: 2022年1月14日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
93
试验地点
4
主要终点
Diagnostic accuracy of CardioFlux

研究概览

简要总结

According to the Women's Ischemic Syndrome Evaluation database, there are approximately 3 to 4 million women and men who present with signs and symptoms that are suggestive of myocardial ischemia, however they have no obstructive coronary artery disease (INOCA). INOCA is defined as patients presenting with signs or symptoms of ischemia but no obstructive artery disease. Women are more likely than men to die from cardiovascular disease and more likely to present with no obstructive coronary artery disease. Patients who present with signs and symptoms suggestive of INOCA/MINOCA are also presenting with Coronary Microvascular Dysfunction (CMD). Coronary Microvascular Dysfunction is a dysfunction in the epicardial and/or microvascular endothelial and/or nonendothelial that limits myocardial perfusion. Today, there is no routinely offered/available noninvasive test that is used for the diagnosis of CMD, significantly hindering the ability to identify the disease in the standard of care. Magenetocardiography (MCG) has the opportunity to use its noninvasive imaging techniques to provide early management of CMD. Magnetocardiography (MCG) is a noninvasive imaging modality that has been extensively studied, over the past several decades, as a diagnostic imaging solution for various forms of cardiovascular disease. MCG measures the magnetic field that arises from the electrical activity of the heart's pacemaker activity, the very same activity which yield surface electric field potentials as measured by the electrocardiogram. Since MCG is a functional assessor of repolarization heterogeneity, it is hypothesized that MCG may be a useful frontline diagnostic to identify CMD in patients who would otherwise have normal coronary CT angiograms and/or stress tests. The proposed study intends to study the diagnostic accuracy of MCG in this population, with the goal of providing early and noninvasive insights for management of CMD. There will be a 12-month duration of the study where the investigators propose to collect MCG scans from approximately 150 patients who present to the Genetesis facility for a 15-minute CardioFlux scan appointment.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 100 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • ≥ 18 years of age at the time of enrollment
  • Signs and symptoms of chest pain that prompted further evaluation by either a heart angiogram or a scan of the heart (coronary CT angiogram) within the previous 5 years
  • Willing to provide written informed consent
  • Non-obstructive CAD defined as 0 to 49% diameter reduction of a major epicardial vessel or a FFR>0.80
  • Scheduled for CRT
  • No cardiac medications in the last 24 hours of an MCG-CF scan (with the exception of the patients enrolled in the data development set)

排除标准

  • Patients unable to fit into device
  • Non-ambulatory patients
  • Patients who meet device contraindications
  • Patients unable to lie supine for 5 minutes
  • History of noncompliance (with medical therapy, protocol, or follow-up)
  • History of non-ischemic dilated or hypertrophic cardiomyopathy
  • Documented acute coronary syndrome (ACS) within previous 30 days
  • Left ventricular ejection fraction (LVEF) <40%, New York Heart Association heart failure (NYHA HF) class III-IV, or hospitalization for Reduced ejection fraction (HFrEF) within 180 days
  • Stroke within previous 180 days or intracranial hemorrhage at any time
  • End-stage renal disease, on dialysis, or estimated glomerular filtration rate (eGFR) <30 ml/min.
  • Severe valvular disease or likely to require surgery/Transcatheter aortic valve replacement (TVAR) within 3 years
  • Life expectancy <3-yrs. due to non-cardiovascular comorbidity
  • Enrolled in a competing clinical trial
  • Prior intolerance to both an ACE-I and ARB
  • If intolerant to a statin unless taking a PCSK9 as a statin replacement by their clinical provider

结局指标

主要结局

Diagnostic accuracy of CardioFlux

时间窗: 12 months

Analyzing the diagnostic accuracy of CardioFlux in determining the presence of coronary microvascular dysfunction

次要结局

未报告次要终点

研究者

申办方类型
Industry
责任方
Sponsor

研究点 (4)

Loading locations...

相似试验