PULSE - Paramètres de l'Impulsion électrique et Population Neuronale Chez le Patient implanté cochléaire - Etude en Ouvert, Non contrôlé, Non randomisée
试验速览
- 阶段
- 不适用
- 状态
- 尚未招募
- 入组人数
- 15
- 主要终点
- Calculate the charge integration efficiency along the electrodes
研究概览
简要总结
The cochlear implant provides good auditory performance despite high inter-individual variability, but performance in noise remains limited. Modification of the coding strategies could improve these performances. A better characterization of the remaining neuronal population by looking for the charge integration efficiency (which depends on the duration and the amplitude of the electrical pulse) would allow an optimization of the settings by adapting either the duration or the amplitude of the pulse according to the quality of the remaining neuronal population.
详细描述
The cochlear implant provides good auditory performance despite high inter-individual variability, but performance in noise remains limited. Modification of the coding strategies could improve these performances. Currently, the intensity perceived by the patient is coded by the duration and the amplitude of the electrical impulse but companies have different approaches and fix one of the two parameters for the setting of the processors. A better characterization of the remaining neuronal population by looking for the charge integration efficiency (which depends on the duration and the amplitude of the electrical pulse) would allow an optimization of the settings by adapting either the duration or the amplitude of the pulse according to the quality of the remaining neuronal population.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Basic Science
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •post-lingually deaf adults with at least one year of cochlear implant experience
- •unilateral and bilateral cochlear implant recipients
- •Oticon device with Neuro Zti array
- •Patient affiliated to french social security
- •Consent signed
排除标准
- •Patients under court protection, guardianship or curatorship
研究组 & 干预措施
Cochlear implant users with Neuro Zti array
Post-lingually cochlear implant users with 12 months of auditory experience Modifications of pulse parameters to determine the charge integration efficiency which is related with neuron survival population
干预措施: Cochlear implant (Oticon) stimulation parameter optimization (Other)
结局指标
主要结局
Calculate the charge integration efficiency along the electrodes
时间窗: 4 hours
Charge integration efficiency will be determined for each electrode by noting the minimum and maximum loudness perceived by the patient as function of pulse phase duration and amplitude
次要结局
- Questionnaire between Intensity discrimination and charge integration efficiency(4 hours)