Bronchoscopy and Electric Impedance Tomography to Investigate the Influence of Bronchoscopy on Pulmonary Regional Ventilation Measurements by Electric Impedance Tomography (EIT)

RWTH Aachen University2 个研究点 分布在 1 个国家目标入组 20 人开始时间: 2011年1月最近更新:
适应症

试验速览

阶段
不适用
入组人数
20
试验地点
2
主要终点
Comparison of the change in lung impedance due to ventilation before and after bronchoscopy by EIT measurements

研究概览

简要总结

Electrical Impedance Tomography (EIT)is a technique based on the injection of small currents and voltage measurements using electrodes on the skin surface generating cross-sectional images representing impedance change in a slice of the thorax. It is a radiation free, non-invasive and portable lung imaging technique. Impedance changes in lung ventilation are investigated in mechanically ventilated patients who routinely undergo bronchoscopy in intensive care medicine. Bronchoscopy is performed to suction secretions as well as to analyze the secretions to recognize inflammations and diseases. It is an essential intervention which causes changes in ventilation which remain for 1-2 hours. It is not completely investigated why these changes in ventilation remain for so long time and how they are distributed regionally. Therefore the purpose of this study is to investigate the change in pulmonary regional ventilation in patients who routinely undergo bronchoscopy to possibly generate ideas how to optimize the ventilation after bronchoscopy to optimize the patient´s treatment.

详细描述

In 20 mechanically ventilated patients who routinely undergo bronchoscopy Electrical Impedance Tomography (EIT) measurements whereby, evaluable data of 10 patients are needed, of about 1-2 minutes are performed directly before, directly after and 10, 30, and 60 minutes after bronchoscopy parallel to the following routine measurements: tidal volume, resistance, compliance, heart rate, blood pressure, SpO2 and blood gas values. Prior to the examination a rubber belt with 16 integrated electrocardiographic electrodes is placed around the thorax connected with an EIT- device. EIT data are generated by application of a small alternating current of 5mA and 50kHz and are stored and analyzed offline on a personal computer. The EIT provides a mapping of the distribution of the lung´s electrical impedance and exhibits a far temporal resolution of up to 40 tomograms per second. Because of electrical impedance of the pulmonal tissue is dependant to the air content, the air distribution within the lung over a certain period can be monitored. Analyzing the EIT- data it might be possible to explain the distribution in regional ventilation and how the ventilation could be optimized right after the bronchoscopy to optimize the patient´s treatment.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Basic Science
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Female and male patients > 18 years old
  • Mechanically ventilated patients who routinely undergo bronchoscopy

排除标准

  • Pregnancy and Breastfeeding
  • Active implants, heart pace makers and implanted converter defibrillator
  • Foreign metallic objects in the thorax
  • Cardiac valves

结局指标

主要结局

Comparison of the change in lung impedance due to ventilation before and after bronchoscopy by EIT measurements

时间窗: Single Measurement of 1.5 hours

It will be investigated if there are changes in lung impedance due to changes in ventilation before, directly after and 10, 30, 60 minutes after bronchoscopy in order to investigate their regional distribution and to generate ideas how the ventilation could be optimized to improve recruitment of the patient´s treatment

次要结局

未报告次要终点