跳至主要内容
临床试验/NCT04848025
NCT04848025招募中不适用

Treatment of Central Airway Stenoses Using Computer-Assisted Customized 3d Stents TATUM (Three-dimensional Airway Tailored Stent Using Computer-aided Modeling)

University Hospital, Toulouse2 个研究点 分布在 1 个国家目标入组 30 人开始时间: 2021年6月17日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
招募中
入组人数
30
试验地点
2
主要终点
Percentage of procedures with clinical improvement of the dyspnea

研究概览

简要总结

Airway stenting is usually efficient to treat central airway obstruction but can lead to severe and potentially lethal complications (stent migration, obstructive granuloma, perforation, and hemoptysis).

3D customized airway stents (computer-aided conception using CT-scan data), perfectly suited to airway anatomy, should improve the tolerance and safety of airway stenting.

We demonstrated in a previous pilot study, dedicated to patients with anatomically complex stenoses the safety of 3D patient-specific stents. These appealing results in highly complex situations suggest the need to evaluate these devices in more common situations.

In this study we aim to test our new generation stents in all patients planned for airway stenting. After computer-assisted segmentation of airways (VGStudioMAX 3.0 software), the stenosis is virtually corrected, leading to the conception of a virtual stent (AnatomikModeling, Toulouse), allowing for the fabrication of a mold using a 3D printer. The stent is then built and sterilized (NOVATECH, Berlin) and inserted during rigid bronchoscopy.

Close follow up is then conducted, including clinical evaluation after one week, three, six and 12 months; spirometry at one week, 3 months, 6 months and 12 months and chest CT-scan at one week.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Age >18 years
  • Informed consent
  • Complex, proximal and symptomatic (dyspnea, cough, peak flow < 50%, FEV1 < 50% or post-stenotic infection) airway stenosis

排除标准

  • Acute respiratory distress, mechanical ventilation
  • Contraindication to rigid bronchoscopy (severe and irreversible coagulation disorders)
  • Pregnancy

研究组 & 干预措施

3D customized airway stents

Experimental

干预措施: Custom-designed tracheobronchial prostheses (Device)

结局指标

主要结局

Percentage of procedures with clinical improvement of the dyspnea

时间窗: 12 months

Percentage of procedures with clinical improvement of the dyspnea with questionnaires of Borg, modified Medical Research Council (mMRC), and Dyspnea 12

Percentage of procedures with clinical improvement of quality of life

时间窗: 12 months

Percentage of procedures with clinical improvement of quality of life with the VQ11 questionnaire

次要结局

  • Percentage of procedures with clinical and functional improvement(12 months)
  • Percentage of procedures without complications(12 months)
  • Percentage of procedures with functional improvement(1 seconde)
  • Percentage of procedures with congruence of the stent(1 week)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验