Ultrasound Detection of Early Facial Muscle Changes in FSHD: Thickness and Echo Intensity Findings - A Cross-Sectional Comparison With Healthy Adults
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 39
- 试验地点
- 1
- 主要终点
- Facial muscle thickness measured by ultrasound
研究概览
简要总结
Facioscapulohumeral muscular dystrophy (FSHD) is characterized by early and significant involvement of facial muscles; however, objective imaging data focusing on facial muscles are limited. Facial ultrasound can serve as a sensitive imaging biomarker and outcome measure by capturing regional structural changes in facial muscles associated with disease progression in FSHD patients.
The aim of this study is to compare facial muscle thickness and echo density between FSHD patients and healthy controls using ultrasound and to examine the relationships between ultrasound findings and clinical parameters.
This study will include 20 patients with genetically confirmed FSHD1 diagnosis and 19 age- and sex-matched healthy controls. Using musculoskeletal ultrasound, bilateral evaluation of selected facial muscles (Orbicularis oculi, orbicularis oris, zygomaticus major, and buccinator) will be performed by two different researchers, and muscle thickness and muscle echo density will be recorded. Inter-rater reliability will be assessed using intraclass correlation coefficients. Group comparisons and correlation analyses will be performed with clinical scores, symptom duration, and D4Z4 repeat size.
The results will evaluate whether ultrasound can reliably detect structural changes in FSHD that cannot be captured by traditional clinical assessments, and if significant, will suggest that ultrasound can serve as a sensitive imaging biomarker for early and region-specific facial muscle involvement in FSHD.
详细描述
Facioscapulohumeral muscular dystrophy (FSHD) is a hereditary neuromuscular disorder characterized by progressive muscle weakness, showing early and significant involvement of facial muscles. Despite their diagnostic and functional importance, facial muscles are often underrepresented in imaging-based assessments of disease involvement. This observational, cross-sectional study was designed to compare structural changes in selected facial muscles of individuals with genetically confirmed FSHD with healthy controls using musculoskeletal ultrasound. The study focuses on the quantitative assessment of muscle thickness and the qualitative assessment of muscle echo density as indicators of atrophy and fat infiltration. Bilateral ultrasound examinations will be performed on facial muscles, including the orbicularis oculi, orbicularis oris, zygomaticus major, and buccinator muscles, which play a role in facial expression and oral function. Imaging findings will be evaluated in relation to clinical features to investigate whether facial muscle ultrasound can provide region-specific information not captured by global disease severity scores. This study aims to characterize facial muscle involvement using a non-invasive and accessible imaging method, contribute to the understanding of early and subclinical facial muscle changes in FSHD, and support the potential role of ultrasound as an imaging biomarker in neuromuscular disorders.
研究设计
- 研究类型
- Observational
- 观察模型
- Other
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 55 Years(Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Adults aged 18-55 years
- •Genetically confirmed facioscapulohumeral muscular dystrophy type 1 (FSHD1) (patient group)
- •Age- and sex-matched healthy volunteers without neuromuscular disease (control group)
- •Ability to provide written informed consent
排除标准
- •Presence of other neurological or neuromuscular disorders
- •History of facial palsy or facial trauma
- •Botulinum toxin injection to facial muscles within the last 6 months
- •Inability to cooperate with ultrasound assessment
结局指标
主要结局
Facial muscle thickness measured by ultrasound
时间窗: Baseline
Bilateral thickness (in millimeters) of the orbicularis oculi, orbicularis oris (superficial and deep layers), zygomaticus major, and buccinator muscles measured using B-mode musculoskeletal ultrasound at standardized anatomical reference points.
Facial muscle echo intensity
时间窗: Baseline
Muscle echogenicity of the same facial muscles assessed bilaterally using the Modified Heckmatt Scale (grades 1-4) to evaluate structural changes and fatty infiltration on B-mode ultrasound images.
次要结局
- Inter-rater reliability of facial muscle ultrasound measurements(Baseline)
研究者
Havvanur Albayrak
Physical Medicine and Rehabilitation Specialist
Koç University