MedPath

Visual Outcome, Cylinder Correction and Patient Satisfaction After Implantation of AT LISA Tri Toric 939MP Intraocular Lenses

Not Applicable
Completed
Conditions
Cataract
Interventions
Device: AT LISA tri toric 939MP
Registration Number
NCT02985723
Lead Sponsor
Carl Zeiss Meditec AG
Brief Summary

The aim of the present study is to evaluate the postoperative visual acuity for distance, intermediate and near vision as well as the cylinder correction and the patient satisfaction after bilateral implantation of AT LISA tri toric 939MP IOLs.

Detailed Description

Not available

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
120
Inclusion Criteria
  • Patient informed of the consequences and constraints of the protocol and who has given his/her written informed consent
  • Man or woman, over 50 years of age
  • Healthy eyes with bilateral cataract requiring surgical treatment for both eyes
  • Bilateral regular corneal astigmatism (confirmed by topography measurement)
  • Only patients requiring intraocular lenses of a power comprised between sphere +0.0 and +28.0 dioptres and between a cylindrical range of +1.0 to +4.0D in both eyes will be able to participate in the trial.
  • Biometry measurement/cataract density compatible with the IOLMaster evaluation
  • Bilateral uncomplicated cataract surgery and implantation into capsular bag by injector
  • Assured follow-up examinations
Exclusion Criteria
  • Patients unable to meet the limitations of the protocol or likely of non cooperation during the trial,
  • Patients whose freedom is impaired by administrative or legal order,
  • Monophtalmic patient.
  • Previous ocular surgery, including corneal/refractive surgery,
  • Chronic or recurrent uveitis,
  • Acute ocular disease or external/internal infection,
  • Any kind of macular degeneration and impairment of retina (clinical diagnosis/OCT examination)
  • Diabetes with retinal changes,
  • Pseudoexfoliation syndrome
  • Pathologic myosis
  • Irregular astigmatism, especially keratoconus,
  • Endothelial corneal dystrophy
  • Glaucoma or IOP higher than 21mmHg under ocular hypertension treatment
  • Aniridia
  • Pseudophakia
  • Cornea guttata; keratoplasty
  • Amotio operation; anamnesis with vitreous surgery
  • Amblyopia
  • Intraocular tumours; endotamponade
  • Phlogistic intraocular processes or other pre-existing processes that permanently limit the best corrected visual acuity to > 0.3 logMAR
  • Any other pathology or condition presenting, according to the investigator opinion, a risk for the patient
  • Pupil diameter over 6 mm in mesopic condition
  • Corneal opacity

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
939MPAT LISA tri toric 939MPAT LISA tri toric 939MP intraocular lens
Primary Outcome Measures
NameTimeMethod
Best distance-corrected visual acuity for intermediate vision after bilateral implantation12 months after surgery
Secondary Outcome Measures
NameTimeMethod
© Copyright 2025. All Rights Reserved by MedPath