Brief Summary

The goal of this prospective randomized controlled study is to investigate the effect of pause of advancement of the Swan-Ganz catheter, which is to check whether the Swan-Ganz catheter arrive exactly at the right ventricle or not, on success rate of final placement and required time in Swan-Ganz catheterization.

The question which the investigators are trying to answer is: Continuous advancement of Swan-Ganz catheter without intended pause in the right ventricle to check whether the Swan-Ganz catheter arrive exactly at the right ventricle will decrease the trial number and required time to success final placement of Swan-Ganz catheter?

Detailed Description

Many clinicians pause advancement of Swan-Ganz catheter to check whether the Swan-Ganz catheter arrive exactly at the right ventricle or not.

The hypothesis of this study is that the intended pause during advancement of Swan-Ganz catheter in the right ventricle induce failure in advancing of it into the pulmonary artery, and that it increase the required time for final placement of it into the pulmonary artery.

Recruitment & Eligibility

Status
UNKNOWN
Sex
All
Target Recruitment
112
Inclusion Criteria
  • The patients who need to Swan-Ganz catheterization for heart surgeries
Exclusion Criteria
  • Who doesn't agree to enroll
  • Who has thrombus in the heart or the vena cavas.

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Primary Outcome Measures
NameTimeMethod
Success rate (%)during Swan-Ganz catheterization procedure

Success rate in placement of Swan-Ganz catheter placement into the pulmonary artery

trial number (n)during Swan-Ganz catheterization procedure

trial number to success placement of Swan-Ganz catheter placement into the pulmonary artery.

required time (seconds)during Swan-Ganz catheterization procedure

total time to success Swan-Ganz catheter placement into the pulmonary artery

Secondary Outcome Measures
NameTimeMethod
direction of placement of Swan-Ganz catheter (n)during Swan-Ganz catheterization procedure

direction of placement of Swan-Ganz catheter between the right pulmoary artery and the left pulmonary artery

incidence of arrhythmia (n)during Swan-Ganz catheterization procedure

incidence of arrhythmia due to Swan-Ganz catheterization

Trial Locations

Locations (1)

Seoul National University Boramae Hospital

🇰🇷

Seoul, Korea, Republic of

Seoul National University Boramae Hospital
🇰🇷Seoul, Korea, Republic of
Jung-Man Lee, M.D.,Ph.D.
Contact
82-10-9553-0916
jungman007@gmail.com

MedPath

Empowering clinical research with data-driven insights and AI-powered tools.

© 2025 MedPath, Inc. All rights reserved.