Association between quantum of linear tooth movement and percentage accuracy in clear aligner therapy - A Retrospective Cohort Evaluation.
试验速览
- 阶段
- 不适用
- 状态
- 尚未招募
- 发起方
- 入组人数
- 450
- 试验地点
- 1
- 主要终点
- The mean accuracy of tooth movement with aligners is expected to range from 40% to 60%, comparing between predicted and actual achieved results for linear tooth movements.
研究概览
简要总结
The retrospective cohort study primarily aims to evaluate and assess the predictability of clear aligners with respect to linear movements in all 3 planes of space. The study also aims to compare the digitally planned tooth movement and the tooth movement clinically achieved at 1st refinement stage. The study further aims to establish correlation between quantum of tooth movement and its percentage accuracy. 450 maxillary and mandibular anterior teeth (approximately 70 teeth in each set) treated using Flash aligner system would be retrospectively selected. Once the model preparation is completed, the pretreatment models would be digitally segmented for isolating individual tooth as separate objects. It would then be compared with unsegmented treatment plan models with Compare 8.1 software (GeoDigm). The following tooth movement (maxillary and mandibular anterior teeth) would be assessed and percentage accuracy would be calculated: Buccal and Lingual movement; Occlusal and Gingival movement; and Mesial and Distal movement. Data gathered would be assembled on a excel sheet and will be processed using appropriate statistical tests on Statistical package for Social Sciences (SPSS) software. Normality of numerical data would be assessed. The normality of data would decide the statistical tests. Considering the above parameters, the mean accuracy of tooth movement of clear aligners is expected to range from 40% to 60%, comparing between predicted and clinically achieved results for linear tooth movements in the current study.
研究设计
- 研究类型
- Observational
入排标准
- 年龄范围
- 18.00 Year(s) 至 32.00 Year(s)(—)
- 性别
- All
入选标准
- •Complete dentition No supernumerary teeth No tooth shape anomalies Good oral hygiene with Healthy periodontium.
- •Minimum 20 Aligner sets have been worn with a mid treatment Intraoral scan done at 20th Aligner.
排除标准
- •Tooth movement less than 0.1mm at the end of stage 20 Systemic pathologies Tooth/Bone related disorders (root resorption) Ongoing pharmacological treatment affecting orthodontic movement(e.g.bisphosphonates) Active periodontal disease Smokers.
结局指标
主要结局
The mean accuracy of tooth movement with aligners is expected to range from 40% to 60%, comparing between predicted and actual achieved results for linear tooth movements.
时间窗: The teeth positions would be assessed at baseline and after 27 weeks.
The study would help establish the relationship between the quantum of tooth movement and the percentage accuracy of tooth movement.
时间窗: The teeth positions would be assessed at baseline and after 27 weeks.
次要结局
- Correlation between quantum of tooth movement and percentage accuracy of tooth movement of maxillary and mandibular anterior teeth.(20 SETS OF ALIGNERS WORN 10 DAY EACH)
研究者
Dr. Chandani Shah
Manav Rachna International Institute of Research and Studies
