MedPath

Efficacy and Safety of Cemented and Cementless Prostheses for Unstable Intertrochanteric Fractures in the Elderly

Not Applicable
Completed
Conditions
Intertrochanteric Fractures
Interventions
Device: cementless Wagner prosthesis
Device: cemented SPII prosthesis
Registration Number
NCT03193697
Lead Sponsor
Harrison International Peace Hospital
Brief Summary

This trial explores the application of different hip replacement materials in elderly patients with unstable intertrochanteric fracture, and aims to provide the experience and basis for hip arthroplasty in elderly osteoporosis patients with unstable intertrochanteric fracture.

Detailed Description

Background Intertrochanteric fractures are common types of hip fractures. With the growth of the global aging population, the elderly fracture patients with osteoporosis are increasing. Thus, the difficulty of treating intertrochanteric fractures increases accordingly. Unstable intertrochanteric fractures refer to the fractures from femoral neck base to lesser trochanter level. With the continuous development of China's aging trend, the number of aging population is increasing gradually; the incidence of unstable intertrochanteric fractures is increasing year by year. Clinically, more than 90% of intertrochanteric fractures occur in the elderly over 65 years of age, and the mortality rate is at a high level. Patients with unstable intertrochanteric fractures are older, and body function gradually degrades. The reduction and fixation of this disease are difficult. Therefore, early to find timely and effective treatment is of great significance to patients with unstable intertrochanteric fractures.

Clinically, internal fixation and artificial joint replacement are the primary methods of treating unstable intertrochanteric fractures. The surgical approach of internal fixation is easily affected by the bone quality of the patients. If the patient has different degrees of osteoporosis, it will lead to the failure of the first operation, affecting the prognosis of the patient. Therefore, this kind of operation method is not accepted gradually in clinical practice. The efficacy of joint replacement for treatment of intertrochanteric fracture is remarkable. It can make the patient obtain the immediate stability and reduce complications, so it is very popular with the patients and physicians in the clinic. The most commonly used artificial joint replacement materials in clinic have two types: cemented and cementless prostheses, but the difference in their efficacies and safeties remains poorly understood.

Adverse events To record adverse events, including incision pain, bone cement poisoning, pulmonary infection, mental disorders and acute cerebral infarction.

If severe adverse events occurred, investigators reported details, including the date of occurrence and measures taken to treat the adverse events, to the principle investigator and the institutional review board within 24 hours.

Data collection, management, analysis and open-access Data collection: Records of all cases reported in the trial were complete, clear and true. The case reports were consistent with the patient's original data and the declared data. The collected data were input to the computer in the record room of Harrison International Peace Hospital.

Data management: Data were processed by a special person, and aggregated once a month. During clinical trials, hospital clinic visits were conducted periodically by the clinical ombudsman to ensure that all the contents of the protocols were strictly observed. Simultaneously, raw data were checked to ensure the consistency with the case report form.

Data analysis: Statistical analysis was performed by professional statisticians. The statisticians wrote the research report and submitted it to the researcher for review.

Data open-access: Anonymized trial data will be published at www.figshare.com.

Statistical analysis Statistical analysis was performed using SPSS 19.0 software (IBM, Armonk, NY, USA) and followed the intention-to-treat principle.

Normally distributed measurement data were expressed as means ± standard deviation and minimums and maximums. Non-normally distributed measurement data were expressed as the lower quartile (q1) and median and upper quartiles (q3). Count data were expressed as the percentage. Two-sample t-test was performed for comparison of Harris hip scores, operation time, intraoperative blood loss, postoperative blood transfusion volume, ambulation time and postoperative amount of drainage in both groups. Repeated measures analysis of variance was conducted for intragroup comparison of Harris hip scores at various time points. Pearson X2 test was carried out for comparison of excellent and good rate of Harris hip scores and incidence of adverse reaction in both groups.

The significance level was α = 0.05.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
86
Inclusion Criteria
  • Unstable intertrochanteric fractures identified by imaging and laboratory examination
  • Age: Greater than 65 years old
  • Irrespective of sex
  • Volunteered to participate in this test, and signed informed consent
Exclusion Criteria
  • Replacement contraindications, such as acute myocardial infarction
  • Obvious obstacles in language communication and communication

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
trial groupcementless Wagner prosthesisOld patients with unstable intertrochanteric fractures underwent total hip arthroplasty. Forty-two patients in the trial group received cementless Wagner prosthesis (Zimmer, USA).
control groupcemented SPII prosthesisOld patients with unstable intertrochanteric fractures underwent total hip arthroplasty. Forty-four patients in the control group received a cemented SPII prosthesis (Link, Germany).
Primary Outcome Measures
NameTimeMethod
Harris hip scoresat postoperative 6 months

To assess the recovery of hip function.The number of patients with excellent and good Harris hip scores/total number of patients × 100%. High excellent and good rate indicates good hip function.

Secondary Outcome Measures
NameTimeMethod
X-rayChanges from preoperative 6 months to postoperative 6 months

To observe morphological changes in the hip.Morphology of the hip was observed in the anteroposterior and lateral images. Heterotopic ossification was classified via the Brooker classification system.

© Copyright 2025. All Rights Reserved by MedPath