简要总结
Prone position in spinal surgery can increase airway pressure and decrease dynamic lung compliance by a frame used for postural stabilization. Also, it can increase hemodynamic instability such as reduced blood pressure by aggravating cardiac index.
Former study shows pressure controlled ventilation on the pulmonary mechanics can improve alveolar use and oxygenation than volume controlled ventilation. The latter one means controlling a patient's breathing completely through tidal volume and set breathing rate. This could be useful for the patients not possible to breath by themselves because it guarantees the perfect breathing.
The pressure controlled ventilation is used when there is a possibility to change a patient's environment. The pressure will be maintained steadily, but volume and flux will be changed. That means through the pressure already set, the whole breathing will be maintained from the beginning to end. If a patient's resistance is increased, the volume will be decreased even though the way of blood pressure control is same. However, the tidal volume per minute can be controlled somewhat and barotrauma can be decreased by controlling respiratory rate. Through this study, we are expecting the pressure controlled ventilation in prone position can improve lung mechanics and oxygenation.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Supportive Care
- 盲法
- Double (Participant, Investigator)
入排标准
- 年龄范围
- 20 Years 至 65 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •scheduled for lumbar spine surgery under general anaesthesia
排除标准
- •Patients with coronary artery occlusive disease
- •morbid obesity (body mass index ≥ 30 kg/m2)
- •cerebrovascular disease and major obstructive or restrictive pulmonary disease
研究组 & 干预措施
PCV
Peak airway pressure were set to deliver a tidal volume of 10 ml/kg of ideal body weight
干预措施: volume control (Procedure)
VCV
After anesthetic induction, anesthesia maching were set to deliver a tidal volume of 10 ml/kg of ideal body weight
干预措施: pressure control (Procedure)
结局指标
主要结局
peak airway pressure
时间窗: 30 minutes after prone position
Record peak airway pressure on anesthesia mechanical ventilator after anesthesia induction and 30 minutes after prone positioning.
次要结局
未报告次要终点