跳至主要内容
临床试验/NCT02160275
NCT02160275已完成不适用

Algorithm to Control Postprandial, Post Exercise and Night Glucose Excursions in a Portable Closed Loop Format, APPEL 4

J.H. DeVries2 个研究点 分布在 1 个国家目标入组 16 人开始时间: 2014年6月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
16
试验地点
2
主要终点
Mean sensor glucose concentration

研究概览

简要总结

In previous studies, we tested the feasibility of a bi-hormonal closed loop system. This system for automated control of blood glucose in patients with type 1 diabetes was tested in the clinical research center as well as at the home of the patients. Glucose control with automated closed loop control was comparable to patient-managed open loop control.

The closed loop system has been further developed and miniaturized (from backpack to smartphone size) in order to interfere as little as possible with daily patient life. The aim of this trial is to assess the efficacy of the new prototype at the home of the patient. It is hypothesized that the closed loop system provides better glucose control than standard open loop therapy.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 75 Years(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Diagnosed with diabetes mellitus type 1
  • •Treated with insulin pump therapy for a minimum of 6 months
  • •Age between 18 and 75 years
  • •Willing and able to sign informed consent

排除标准

  • •Impaired awareness of hypoglycemia (score ≥ 4) according to Gold and/or Clarke questionnaire
  • •BMI > 35 kg/m2
  • •HbA1c > 97 mmol/mol (=11.0 %)
  • •Use of heparin, coumarin derivatives or oral corticosteroids
  • •Skin condition prohibiting needle insertion
  • •Pregnancy and/or breastfeeding
  • •Living alone during the closed loop period (the patient may ask someone to stay over temporarily)
  • •Any condition that the local investigator feels would have interfere with trial participation or the evaluation of the results

研究组 & 干预措施

Open Loop

Active Comparator

4 days patient-managed insulin pump therapy with blinded continuous glucose monitoring

干预措施: Insulin pump therapy (Device)

Closed Loop

Experimental

4 days of automated blood glucose control with the Artificial Pancreas (Inreda Diabetic BV)

干预措施: Artificial Pancreas (Inreda Diabetic BV) (Device)

结局指标

主要结局

Mean sensor glucose concentration

时间窗: Day 2-4

次要结局

  • Mean sensor glucose concentration during specific periods(Day 2-4)
  • Number of carbohydrate-treated hypoglycemic events(Day 2-4)
  • Number of events in each glycemic category(Day 2-4)
  • Proportion of time spent in each glycemic category(Day 2-4)
  • Proportion of time spent in euglycemia (≥ 3.9 mmol/l and ≤ 10 mmol/l)(Day 2-4)
  • Glycemic variability(Day 2-4)
  • Mean absolute relative difference between sensor values and self-monitored blood glucose values(Day 2-4)
  • Heart rate(Day 2-4)
  • Time that the control algorithm is inactive(Day 1-4)
  • Physical activity(Day 2-4)
  • Mean glucose concentration per day(Day 1-4)

研究者

发起方
J.H. DeVries
申办方类型
Other
责任方
Sponsor Investigator
主要研究者

J.H. DeVries

Principal Investigator

Academisch Medisch Centrum - Universiteit van Amsterdam (AMC-UvA)

研究点 (2)

Loading locations...

相似试验