研究概览

简要总结

The study explores the benefits from the application of an all-in-one health monitoring device by care staff in old-age home setting: whether the average time consumed for measuring vital signs (including temperature, blood pressure and SpO2) will be shortened after the adoption of the new device. The study also assesses the satisfaction and perceived usability of the stakeholders towards the all-in-one health monitoring device.

详细描述

Study design

This is a single-group experimental 10-week trial of comparing the time consumed for measuring health indicators by using the new all-in-one health monitoring device and using the traditional devices, using days as the analysis unit (i.e. comparing the time consumed in two measurements on same days). Before the trial, there will be a 2-week period of device piloting and calibration, so all residents will be measured by the new device for 12 weeks. Views and comments from the operation staff on the usage of the device will also be collected.

Subjects

Care staff and residents in Haven of Hope Woo Ping Care & Attention Home & Haven of Hope Nursing Home will be recruited for the main analysis. If residents are competent in giving consent, both residents and their guarantor, who are responsible for making decisions and signing documents for the residents, will be approached for consent. In cases residents are not competent in giving consents, only their guarantor will be approached for consent.

Procedures

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Prospective

入排标准

性别
All
接受健康志愿者

入选标准

  • 未提供

排除标准

  • 未提供

结局指标

主要结局

Average time required for health monitoring operation during the 12-week period

时间窗: 12 weeks

The change in average daily operation time from using all-in-one health monitoring device compared to using traditional devices. The daily operation time from using all-in-one health monitoring device is recorded in log sheets by the staff.

次要结局

  • Qualitative measure: Perceived benefits in using all-in-one health monitoring device(at the end of 12-week trial period)
  • Qualitative measure: Perceived acceptance in using all-in-one health monitoring device(at the end of 12-week trial period)
  • Qualitative measure: Perceived concerns in using all-in-one health monitoring device(at the end of 12-week trial period)