Brief Summary

The purpose of this study is to measure the sensitivity and specificity of ultrasound exam of the hip in diagnosing occult hip fractures.

Detailed Description

Introduction: Most hip fractures are diagnosed by history, physical examination and confirmed by plain radiographs. When initial X-rays are negative or equivocal, and there is a clinical suspicion of occult hip fracture, additional diagnostic tests are necessary such as MRI which is expensive and in many hospitals less available, or bone scan which needs to be delayed 48-72 hours from injury to be indicative. Ultrasound examination has been shown to be an accurate measurement to diagnose occult fractures in the ankle and is a relatively easy, available, non-expansive examination. We propose the use of bedside ultrasound examination of the hip as a screening tool for occult hip fractures.

Objective: To measure the sensitivity and specificity of ultrasound exam of the hip in diagnosing or ruling out occult hip fractures.

Materials and methods: We will include all patients 40 years and older with a painful hip after an injury, and with "normal" hip X-rays. Each patient will undergo two hip ultrasounds by two different examiners. Afterwards, the patients will undergo MRI of the hip. The MRI will serve as the gold standard for treatment decisions. The results of the ultrasound will be compared to the MRI to evaluate its sensitivity and specificity.

Recruitment & Eligibility

Status
UNKNOWN
Sex
All
Target Recruitment
30
Inclusion Criteria
  • Patients aged 40 years or older, with suspected hip fracture but normal plain X-rays
Exclusion Criteria
  • Patients younger than 40 years and with contra-indications for MRI scan

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Primary Outcome Measures
NameTimeMethod
Comparison between ultrasound exam and MRI (sensitivity and specificity)2008
Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Hadassah Medical Organization

🇮🇱

Jerusalem, Israel