MedPath

Passive Fit of CAD/CAM Screw-retained Metal Frameworks Versus Screwmented Ones

Not Applicable
Conditions
Jaw
Edentulous
Interventions
Procedure: Digitally constructed frameworks before implant placement
Procedure: Digitally constructed frameworks after implant placement
Registration Number
NCT04372901
Lead Sponsor
Cairo University
Brief Summary

CAD/CAM (computer aided design/ computer aided manufacturing) constructed screw retained implant supported frameworks give solutions for the problems arising from the lost wax technique by improving accuracy, adaptation and passive fit of the final restoration. However, concerns about the passive fit of a pre-implant insertion CAD/CAM constructed framework still exists due to the expected errors in imaging, registration, surgical guide construction, adaptation and hence transferring the planned position intra-orally.

Detailed Description

9. PICO Format: Population: mandibular free end saddle requiring 2 implants. Intervention: Digitally fabricated screw-mented retained metal frameworks constructed before implant placement Control: Digitally fabricated screw retained metal frameworks constructed after implant placement

Outcome:

Outcome Measuring device Measuring unit Passive fit One screw test Binary 13 Screw resistance Binary Radiographic ( digital periapical radiography) Binary III. Methods A) Participants, interventions \& outcomes 9. Study settings: i. The study will be conducted at Department of Oral Implantology, faculty of oral and dental medicine, Cairo University, Egypt. ii. Participants will be selected from the outpatient clinic of implantology department, faculty of oral and dental medicine, Cairo University, Egypt. 10. Eligibility criteria: A-Inclusion criteria: i- Mandibular Kenndy Class I. ii- Opposing completely dentulous, fully or partially restored dentition. iii- Good oral hygiene. iv- The patient should have bone for implants, minimum bone height 10 mm and minimum bone diameter should be 6 mm. v- Adequate inter arch space for restoration 15mm or more. vi- Adult patients age ≥18 years B- Exclusion criteria: i. any medical disorder that could complicate surgical phase or affect osteointegration. Radiation chemotherapy. ii. smokers more than 10/daily. iii. Uncooperative patients. iv. Patients with Para-functional habits v. Patients with severe periodontal diseases. vi. Patients with limited mouth opening. vii. Presence of intraoral pathological lesions. viii. Diabetic (HbA1c \>7.5%).

Recruitment & Eligibility

Status
UNKNOWN
Sex
All
Target Recruitment
8
Inclusion Criteria
  • Mandibular Kenndy Class I.
  • Opposing completely dentulous, fully or partially restored dentition.
  • Good oral hygiene.
  • The patient should have bone for implants, minimum bone height 10 mm and minimum bone diameter should be 6 mm.
  • Adequate inter arch space for restoration 15 mm or more.
  • Adult patients age ≥18 years
Exclusion Criteria
    • . any medical disorder that could complicate surgical phase or affect osteointegration. Radiation chemotherapy.
  • ii. smokers more than 10/daily.
  • iii. Uncooperative patients.
  • iv. Patients with Para-functional habits
  • v. Patients with severe periodontal diseases.
  • vi. Patients with limited mouth opening.
  • vii. Presence of intraoral pathological lesions.
  • viii. Diabetic (HbA1c >7.5%)

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
digitally constructed frameworks before implant placementDigitally constructed frameworks before implant placementIntervention group in which the edentulous area will be restored with 3-implant screwmented CAD/CAM frameworks constructed based on planned implant positions.
digitally constructed frameworks after implant placementDigitally constructed frameworks after implant placementControl group: edentulous area will be restored with 3-implant conventional screw retained CAD/CAM frameworks constructed after implant placement
Primary Outcome Measures
NameTimeMethod
Passive fit10 weeks

Evaluation of Passive fit between CAD/CAM Implant Supported Screw-retained Metal Frameworks Based on Actual Versus Screwmented Ones Based on Virtual Implant Position using one screw test .

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Faculty of dentistry

🇪🇬

Cairo, Manial, Egypt

© Copyright 2025. All Rights Reserved by MedPath