MedPath

Does the Structure of the Tendon Relate to the Temporal, Kinetic and Kinematic Jump Variables? Athletes Vs. Non Athletes

Active, not recruiting
Conditions
Vertical Jump
Patellar Tendon
Achilles Tendon
Registration Number
NCT06732986
Lead Sponsor
Escola Superior de Tecnologia da Saúde do Porto
Brief Summary

The goal of this observational study is to investigate the relationship between temporal, kinetic, and kinematic jump variables and patellar and Achilles tendons' structure in athletes and non-athletes. The main research questions are:

Does the structure of the patellar and Achilles tendons relate to the temporal, kinetic, and kinematic jump variables? Does the relationship between these variables differ between athletes and non-athletes? To answer these questions, researchers will compare the two groups to determine if the relationships between the variables are similar. Participants will undergo a UTC (Ultrasound Tissue Characterization) scan of the patellar and Achilles tendons and perform five jumps: a countermovement jump, a single-leg countermovement jump on each leg and a single-leg horizontal jump on each leg.

Detailed Description

Not available

Recruitment & Eligibility

Status
ACTIVE_NOT_RECRUITING
Sex
All
Target Recruitment
48
Inclusion Criteria

Not provided

Exclusion Criteria

Not provided

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Primary Outcome Measures
NameTimeMethod
Tendon StructureBaseline

Ultrasound Tissue Characterization (UTC) captures tendon structure and quantifies the number of altered fibers. This technology classifies tendon structure into four echo types, reflecting tendon integrity and fibrillar organization. Data collection for the patellar tendon will be conducted with participants seated, hips and knees at 90° flexion, and feet supported on a stable surface. For the Achilles tendon, the participants will be lying down with ankle in neutral position.

This positioning ensures the probe is aligned transversely to the tendons, enabling the acquisition of optimal ultrasound images without anisotropy.

Ultrasound parameters will be standardized for all scans: a 40-second B-mode ultrasound using a 7-10 Hz linear transducer, with the probe attached to a tracking device that moves automatically along the tendon's perpendicular axis, capturing consecutive images at 0.2 mm intervals. A single scan of the tendons will be performed for each knee.

Jump VariablesBaseline

The data collection protocol includes the following tasks: countermovement jump, single-leg countermovement jump with the dominant leg, single-leg countermovement jump with the jumping leg, single-leg horizontal jump with the jumping leg and single-leg horizontal jump with the dominant leg. Kinematic variables will be analyzed by recording the spatial positions of reflective markers placed on specific anatomical regions. Data will be captured using the Qualisys Motion Capture System (version 2021.2).

Ground reaction forces will be measured using a force platform connected to a signal amplifier. The platform records the three components of ground reaction forces-anteroposterior, mediolateral, and vertical-via four sensors.

The image capture hardware is connected to the Qualisys USB Analog Acquisition interface, synchronizing temporal, kinetic, and kinematic data with the Qualisys Track Manager (QTM) software.

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Escola Superior de Saúde do Instituto Politécnico do Porto

🇵🇹

Porto, Portugal