MedPath

Effects of HBO on Glucose in Patients With DM

Not Applicable
Suspended
Conditions
Diabetes Mellitus, Type 1
Diabetes Mellitus, Type 2
Interventions
Device: Hyperbaric Oxygen
Registration Number
NCT04261738
Lead Sponsor
Legacy Health System
Brief Summary

The purpose of this Research Study is:

1. To determine the reliability and performance of the Dexcom G6® continuous glucose monitoring (CGM) system in patients with diabetes undergoing hyperbaric oxygen (HBO2) exposure. The study-specific blood glucose meter and CGM system are approved by the FDA (U.S. Food and Drug Administration).

2. To determine whether HBO2 exposure causes blood glucose to drop as a result of the treatment.

3. To determine whether HBO2 causes a change in blood glucagon (a hormone that raises blood glucose).

Investigators will be comparing changes in blood glucose and glucagon in volunteers with diabetes who will be exposed to a single hyperbaric oxygen treatment (pressurization to 2.4 atmospheres absolute for 90 minutes) to a control period of 2 hours where volunteers will simulate a hyperbaric treatment while sitting in an examination room breathing room air at sea level pressure. Investigators will be measuring blood glucose with a variety of devices including a continuous glucose monitor, two point-of-care glucometers, and the hospital inpatient laboratory measurement of venous blood.

Detailed Description

The purpose of this Research Study is to determine whether the Dexcom G6® continuous glucose monitoring (CGM) system accurately estimates blood glucose in diabetic patients undergoing hyperbaric oxygen (HBO2) exposure. The study-specific CGM system is approved by the FDA (U.S. Food and Drug Administration).

Subjects will have the Dexcom CGM inserted underneath the skin of their abdomen. This is done in the office. It is secured to the skin by use of an adhesive patch. The sensor measures glucose levels just underneath the skin. A transmitter is fastened on top of the sensor and sends this information wirelessly to a receiver or compatible smart device. Study participants will also have second sensor inserted in the subcutaneous tissue on the back of the arm as a backup in case of data loss. The subjects will wear the sensors for at least 48 hours and then return to the Hyperbaric Medicine Clinic.

At the Hyperbaric Medicine Clinic, study staff will check the CGM system to make sure it has been working properly. The first 2-hour session will be a control where participants will sit quietly (as they would in the hyperbaric chamber) and will not be allowed to consume carbohydrates unless directed to by the hyperbaric department hypoglycemia protocol. The following day for the HBO2 session, subjects will be fitted for an oxygen hood and given a standard HBO2 treatment. Investigators will obtain concurrent transcutaneous oximetry measurements (TCOM) attached no farther than 3 cm from the commercial CGM on the abdomen to measure tissue oxygenation in the region of the CGM only during HBO2 exposure.

The hyperbaric oxygen therapy chamber can accommodate 12 patients at a time. Study subjects could be in the chamber along with regularly scheduled patients. In the chamber the pressure will increase to approximately 2-1/2 times normal atmospheric pressure (2.4 atmospheres absolute \[ATA\]). Once they reach the treatment pressure, subjects will breathe oxygen by placing the hood over their head and securing it in place. They will breathe oxygen for a 30-minute period, and then take the hood off for 5 minutes for an "air break." They will have a total of three 30-minute oxygen periods and two 5-minute air breaks. A subject will be in the hyperbaric chamber for approximately 2 hours.

Blood sampling will be identical for both the control and HBO2 exposure days. Subjects will have a peripheral intravenous (IV) catheter placed and a total of 12 samples collected to measure venous blood glucose (12 timepoints), glucagon levels (3 timepoints) and HgA1c, (one time). A RN or MD will be inside the chamber to monitor the subjects and to obtain the IV blood samples. Because CGMs have not been established to be reliable under HBO2 conditions in patients with DM, the protocol will collect Point-of-Care (POC) glucose measurements using the hospital's standard glucometer (Nova Biomedical, Waltham, MA) and the AccuChek Inform II POC glucometer (Roche Diagnostics, Indianapolis, IN) at each testing point. This will be done using a lancet to pierce the skin of the fingertip to get a drop of blood.

Subjects in both groups will also be required to perform home glucose monitoring (4 times per day) and record mealtimes and the time of any medications taken throughout the study period.

Subjects will return to the clinic on Day 10. The CGM sensor will be removed and the transmitter and display device collected by staff. Removed sensors will be returned to the manufacturer for analysis. That is the end of the subject's study participation.

Recruitment & Eligibility

Status
SUSPENDED
Sex
All
Target Recruitment
24
Inclusion Criteria
  • Diagnosis of type 1 or type 2 diabetes
  • Willing to have 2 subcutaneous glucose monitors for 10 days
  • Willing to be NPO after midnight on the day of the study session
  • Willing to come to the hyperbaric facility on successive days (one control session and one hyperbaric treatment), spending approximately 3 hours in the facility on each day of testing
  • Willing to undergo multiple fingersticks on the days of testing
  • Willing to have a peripheral intravenous catheter placed for blood sampling
  • Willing to perform four daily fingerstick blood glucose checks throughout the study period
Read More
Exclusion Criteria
  • Contraindication to HBO2 as determined by the study investigator (e.g., pregnancy)
  • Previous treatment with HBO2 within 30 days of enrollment
  • Current use of CGM is not an exclusion, but participants must use study equipment during the study
  • Current use of an insulin pump
  • Known allergy to medical-grade adhesives
  • Extensive skin changes/disease that preclude wearing the sensor on normal skin (e.g. extensive psoriasis, recent burns or severe sunburn, extensive eczema, extensive scarring, extensive tattoos, dermatitis herpetiformis)
Read More

Study & Design

Study Type
INTERVENTIONAL
Study Design
SEQUENTIAL
Arm && Interventions
GroupInterventionDescription
Hyperbaric OxygenHyperbaric OxygenThe following day for the HBO2 session, subjects will be fitted for an oxygen hood and given a standard HBO2 treatment. In the chamber the pressure will increase to approximately 2-1/2 times normal atmospheric pressure (2.4 atmospheres absolute \[ATA\]). Once they reach the treatment pressure, subjects will breathe oxygen by placing the hood over their head and securing it in place. They will breathe oxygen for a 30-minute period, and then take the hood off for 5 minutes for an "air break." They will have a total of three 30-minute oxygen periods and two 5-minute air breaks. A subject will be in the hyperbaric chamber for approximately 2 hours.
Primary Outcome Measures
NameTimeMethod
CGM Reading10 days

Estimated glucose value from the continuous glucose monitor

Fingerstick point of care glucose10 days

Estimated glucose value from fingersticks during the length of the study (4 times/day)

CGM Reading from Data Logger10 days

Estimated glucose value from the data logger

Hospital laboratory glucose2 days

Estimated glucose value from venous blood during control and HBOT arms

Hba1cOne time only on day 3 of study

Baseline Hba1c

Secondary Outcome Measures
NameTimeMethod
Glucagon2 days

We will determine whether HBOT has any effect on glucagon levels on control and HBOT arm

Trial Locations

Locations (1)

Legacy Emanuel Medical Center

🇺🇸

Portland, Oregon, United States

© Copyright 2025. All Rights Reserved by MedPath