跳至主要内容
临床试验/NCT04433039
NCT04433039已完成不适用

COVID-19 Versus H1N1 Viral Pneumonia: A Retrospective Comparative Study for Spectrum of HRCT Findings Among 130 Patients

Alexandria University1 个研究点 分布在 1 个国家目标入组 130 人开始时间: 2020年5月22日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
130
试验地点
1
主要终点
COVID19 versus H1N1; radiological comparative study

研究概览

简要总结

Background: Till the moment of editing this paperwork, WHO announced that there is no specific drugs or vaccines for treatment or prophylaxis of COVID-19. Additionally during the global gradual unlocking of community restrictions, WHO warned form another wave of the disease during the next few months. So clinicians and radiologists during this second wave would face great challenges in differentiation between COVID-19 and other virulent influenza viruses, mainly H1N1.

Objective: to establish comparative radiological study between COVID19 and H1N1 to find differentiating criteria that would help during their expected clinico-laboratory and radiological overlap in next Influenza season.

Material and methods: Retrospective study was including 130 patients; 65 COVID-19 patients and 65 H1N1 patients. HRCT findings to be analyzed by three expert consultant radiologists.

详细描述

A. Study population and medical records review:

Inclusion criteria: 65 COVID-19 and 65 H1N1 patients to be enrolled. Exclusion criteria: (1) Degraded quality of CT scans due to patient unavoidable tachypnea with respiratory motion artifacts. (2) Unremarkable CT scans were also excluded. (3) Past history of large airway disease, asthma, COPD or bronchiectasis. (4) Patients with secondary bacterial infection.

B. CT scanning and parameters:

CT examinations conducted using multiple MDCT machines including: GE LightSpeed Plus 4 slice CT scanner (USA), Philips Brilliant-16 (USA), Siemens SOMATOM Emotion 16 and Siemens SOMATOM Sensation 64 (Germany), Toshiba Aquilion 64 and Toshiba Aquilion CXL/CX 128 (USA).

CT Scanning parameters : Slice thickness: 1 - 1.25 mm. Volumetric HRCT table speed with least cycles of breath holds as possible. Tube rotation: 0.6-0.9 second. Detector Collimation 1 mm. Helical mode (volumetric HRCT). kVp and mA per slice: 120 - 130 kVp and 200-400 mA, according to the type of MSCT machine used, the weight of the patient and the clinical indication.

研究设计

研究类型
Observational
观察模型
Case Crossover
时间视角
Retrospective

入排标准

年龄范围
4 Years 至 80 Years(Child, Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients with COVID-19 or H1N1

排除标准

  • (1) Degraded quality of CT scans due to patient unavoidable tachypnea with respiratory motion artifacts. (2) Unremarkable CT scans were also excluded. (3) Past history of large airway disease, asthma, COPD or bronchiectasis. (4) Patients with secondary bacterial infection.

结局指标

主要结局

COVID19 versus H1N1; radiological comparative study

时间窗: "through study completion, an average of 20 days"

Find HRCT differences between COVID-19 and H1N1

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Ahmed Samir

Lecturer of radio-diagnosis

Alexandria University

研究点 (1)

Loading locations...

相似试验