跳至主要内容
临床试验/NCT06576908
NCT06576908已完成不适用

Evaluation of Image Quality From an On-Couch, Cone Beam Computed Tomography (CBCT) Radiation Treatment System for Image Guidance and Treatment Adaptation

Varian, a Siemens Healthineers Company2 个研究点 分布在 1 个国家目标入组 46 人开始时间: 2024年10月17日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
46
试验地点
2
主要终点
Comparison of overall free-breathing image quality: HyperSight CBCT vs Conventional CBCT

研究概览

简要总结

This is a prospective, single-arm, single-site study designed to generate data describing the image quality and applicability/useability of a high-performance, on-couch CBCT imaging technology (HyperSight) in patients receiving radiation treatment for cancer on a C-arm linear accelerator (TrueBeam).

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Other
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patient age is ≥ 18 years old.
  • Patient has a diagnosis of primary or metastatic cancer, including but not limited to tumors arising from or involving the head/neck, lungs, liver, pancreas, prostate, urinary bladder, rectum, cervix or uterus.
  • A previous (standard-of-care) decision was made to treat the patient with radiation therapy using a Varian TrueBeam treatment system.
  • A previous (standard-of-care) decision was made to treat the patient with a radiation dose of at least 20 Gy in at least 5 fractions, one fraction per day on consecutive days, Monday to Friday.
  • Patient is willing and able to provide informed consent to participate in the study.

排除标准

  • Patient is pregnant or has plans for pregnancy during the period of treatment.
  • Patient is part of a vulnerable population (per ISO 14155:2020, "individuals who are unable to fully understand all aspects of the investigation that are relevant to the decision to participate, or who could be manipulated or unduly influenced as a result of a compromised position, expectation of benefits or fear of retaliatory response").

研究组 & 干预措施

HyperSight Imaging arm

Experimental

Subjects have both HyperSight and conventional CBCT imaging.

干预措施: HyperSight Imaging (Device)

结局指标

主要结局

Comparison of overall free-breathing image quality: HyperSight CBCT vs Conventional CBCT

时间窗: Day 1 of radiation treatment, day 2 of radiation treatment, and the last day of radiation treatment (up to 6 weeks after the start of treatment).

Semi-quantitative scoring (5-point Likert scale) of on-treatment, free-breathing HyperSight-TrueBeam CBCT images compared to on-treatment, free-breathing conventional TrueBeam CBCT images by three independent observers. The Likert scale values will represent a range of opinion from strong preference for HyperSight-TrueBeam CBCT images to strong preference for conventional TrueBeam CBCT images.

次要结局

  • Comparison of metal artifacts: HyperSight CBCT vs. Conventional CBCT(Day 1 of radiation treatment, day 2 of radiation treatment, and the last day of radiation treatment (up to 6 weeks after the start of treatment).)
  • Comparison of overall breath hold image quality: HyperSight CBCT vs Conventional CBCT(Day 1 of radiation treatment, day 2 of radiation treatment, and the last day of radiation treatment (up to 6 weeks after the start of treatment).)
  • Comparison of Hounsfield Unit accuracy: HyperSight CBCT vs Conventional CBCT and CT Simulation images(Day 1 of radiation treatment, day 2 of radiation treatment, and the last day of radiation treatment (up to 6 weeks after the start of treatment).)
  • Comparison of motion artifacts: HyperSight CBCT vs. Conventional CBCT(Day 1 of radiation treatment, day 2 of radiation treatment, and the last day of radiation treatment (up to 6 weeks after the start of treatment).)
  • Comparison of overall image quality: HyperSight CBCT vs Computed Tomography (CT) simulation images(Day 1 of radiation treatment, day 2 of radiation treatment, and the last day of radiation treatment (up to 6 weeks after the start of treatment).)
  • Breath hold imaging time(Day 1 of radiation treatment, day 2 of radiation treatment, and the last day of radiation treatment (up to 6 weeks after the start of treatment).)
  • Patient's perspectives of on-treatment HyperSight-TrueBeam CBCT(Day 1 of radiation treatment and the last day of radiation treatment (up to 6 weeks after the start of treatment).)
  • Patient tolerability of on-treatment, breath-hold HyperSight-TrueBeam CBCT imaging.(Day 1 of radiation treatment, day 2 of radiation treatment, and the last day of radiation treatment (up to 6 weeks after the start of treatment).)

研究者

发起方
Varian, a Siemens Healthineers Company
申办方类型
Industry
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验