跳至主要内容
临床试验/NCT03215329
NCT03215329Unknown不适用

Comparison of Stroke Volume Variation During Alveolar Recruitment With Stepwise Increase in Positive End Expiratory Pressure and Continuous Positive Airway Pressure (30cmH2O During 30 Seconds) in Anesthetised Patients

University Hospital, Caen1 个研究点 分布在 1 个国家目标入组 50 人开始时间: 2017年1月2日最近更新:
适应症

试验速览

阶段
不适用
入组人数
50
试验地点
1
主要终点
change in stroke volume

研究概览

简要总结

During general anaesthesia, pulmonary atelectasis has been shown to occur in 85 to 90% of patient. Pulmonary atelectasis increases occurrence of postoperative pulmonary complication including pneumoniae. Pulmonary atelectasis can be prevented or reversed by alveolar recruitment manoeuvres (ARM). Two methods for ARMs have been described. A sustained continuous positive airway pressure (CPAP) or a stepwise increase in PEEP.The transient increase in intrathoracic pressure during ARMs decreases venous return and increases pulmonary vascular resistance. This result in a decrease in right and left ventricular stroke volume (SV). Finally, the deleterious hemodynamic effects of ARMs may be exacerbated by hypovolemia, heart failure, and in patients with chronic treatment wich impedes cardiovascular responses to hypovolemia. At our best knowledge, there is no study which compared the hemodynamic effects of ARM using sustained CPAP or stepwise increase in PEEP. Consequently, the present study was designed to examine the hemodynamic effects of 2 ARM methods in anesthetized patients.

详细描述

This is a single-centre prospective observational study performed in operating rooms of the university hospital of Caen.

Inclusion criteria were adult patients aged 18 year and above, American Society of Anesthesiologists physical status II to IV, scheduled for intermediate and high risk abdominal and vascular surgery (as defined by the european guidelines on non-cardiac surgery: cardiovascular assessment and management), and equipped with a radial arterial catheter and transoesophageal doppler monitor Patients less than 18 year-old, adults under protection, pregnant women, patients with atrial fibrillation, history of right ventricular dysfunction, known left ventricular ejection fraction < 30%, or preoperative pulmonary disease were excluded.

After intravenous line placement and monitoring (IntelliVue MP70 Philips HealthCare, Amsterdam, The Netherlands) with continuous 5-lead electrocardiography, pulse oximetry, and bispectral index, after local anaesthesia a radial intra-arterial catheter was inserted and connected to a pressure transducer zeroed at the intersection of the mid axillary line and the fifth intercostal space. Arterial pressure and pulse pressure variation (PPV) were continuously displayed on the IntelliVue MP70 monitor. After a 3 to 5 min preoxygenation, anaesthesia was induced and maintained using target-controlled total intravenous anaesthesia with propofol and remifentanil. If a neuromuscular blocking agent was administered its effect was monitored by accelerometry at the thumb following Train-of-Four stimulations of the ulnar nerve repeated every 30 seconds. Following orotracheal intubation; patients were ventilated with controlled ventilation mode (inspired Oxygen fraction 40%, tidal volume: 8ml.kg-1, PEEP at +5 to +8 cmH2O, inspiratory to expiratory ratio of ½, respiratory rate between 10 and 15 min-1 to maintain an end-tidal carbon dioxide partial pressure of 30 to 35 mmHg). An oesophageal Doppler probe connected to its monitor was inserted after tracheal intubation (CardioQ-ODM, Deltex Medical, UK). Then, a fluid challenge was performed with 250 ml of colloid or crystalloid at the discretion of anaesthesiologist and repeated if the SV increased by more than 10%.

The first ARM was performed after orotracheal intubation and SV optimisation. Two preset ARM were available on the anaesthesia respirator: CPAP at 30 cmH2O for 30 seconds (CPAP30) and a stepwise increase and decrease in PEEP (PEEPsteps). The choice of the ARM was left at the discretion of the attending anaesthesiologist.

Heart rate, arterial pressure (systolic, diastolic, mean), PPV, pulse oximetry, cardiac index (CI), SV, peak velocity (PV), corrected flow time (FTc, averaged across 10 successive measurements), and bispectral index were recorded by an independent observer before the ARM, during the ARM at the nadir of SV variation, and 1 (after1) and 3 (after3) min after the end of the ARM.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • adult patients aged 18 year and above, American Society of Anesthesiologists physical status II to IV, scheduled for intermediate and high risk abdominal and vascular surgery (as defined by the guidelines on non-cardiac surgery: cardiovascular assessment and management), and equipped with a radial arterial catheter and transoesophageal doppler monitor

排除标准

  • Patients less than 18 year-old, adults under protection, pregnant women, patients with atrial fibrillation, history of right ventricular dysfunction, known left ventricular ejection fraction < 30%, or preoperative pulmonary disease

结局指标

主要结局

change in stroke volume

时间窗: before and during the alveolar recruitment maneuver

stroke volume measured by transoesophageal doppler probe

次要结局

  • arterial pressure(before, during, 1 and 3 min after the alveolar recruitment maneuver)
  • pulse pressure variation(before, during, 1 and 3 min after the alveolar recruitment maneuver)
  • Corrected Flow Time(before, during, 1 and 3 min after the alveolar recruitment maneuver)
  • cardiac index(before, during, 1 and 3 min after the alveolar recruitment maneuver)
  • heart rate(before, during, 1 and 3 min after the alveolar recruitment maneuver)
  • peak velocity(before, during, 1 and 3 min after the alveolar recruitment maneuver)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验