跳至主要内容
临床试验/NCT06051370
NCT06051370已完成不适用

Ultrasound-guided Glenohumeral Versus Subacromial Steroid Injections for Impingement Syndrome With Mild Stiffness: A Randomized Controlled Trial

Chuncheon Sacred Heart Hospital2 个研究点 分布在 1 个国家目标入组 51 人开始时间: 2013年1月12日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
51
试验地点
2
主要终点
Range of motion (ROM)

研究概览

简要总结

A prospective randomized controlled trial enrolled 51 patients diagnosed with shoulder impingement syndrome and mild stiffness.

Patients were randomly assigned to two groups: the glenohumeral injection group (Group GH) or the subacromial injection group (Group SA). After the final follow-up, 48 patients (24 in each group) were included for analysis Using ultrasound guidance, a solution containing 1mL of triamcinolone, 4mL of 1% lidocaine, and 7mL of 0.9% normal saline was injected into either the glenohumeral or the subacromial space. The following assessments were conducted at baseline and during follow-up visits at weeks 3, 7, and 13: ROM measurements for forward elevation, external rotation, and internal rotation; clinical scores including VAS, ASES, and Constant.

详细描述

Patient Enrollment Following approval from the Institutional Review Board and in compliance with the Declaration of Helsinki, a prospective randomized controlled trial was conducted from January 2013 to June 2014, involving 56 patients diagnosed with shoulder impingement syndrome with mild stiffness. Impingement syndrome was diagnosed based on positive Hawkin's sign and radiographic findings (rotator cuff with intact continuity but tendinosis confirmed by MRI or ultrasound, with a possible subacromial enthesophyte). "Mild" stiffness was defined in this study as a degree of stiffness that permits activities of daily activity but still often causes endpoint ROM pain. It was specified as meeting two or more of the following criteria in shoulder range of motion both passive and active: abduction between 110˚ and 150˚, forward elevation between 120˚ and 140˚, external rotation at the side between 30˚ and 50˚, and internal rotation at 90˚ of abduction between 30˚ and 50˚.

Patients were excluded from the study if they (1) refused to undergo ultrasound-guided injection, (2) were diagnosed with a rotator cuff tear, calcific tendinosis, or biceps pathology, (3) had a history of operation, fracture, or nerve injury of the shoulder, or (4) received treatment apart from the protocol during the study. A final number of 51 patients were enrolled in the trial and randomly assigned to either the glenohumeral ultrasound-guided injection group (Group GH) or the subacromial ultrasound-guided injection group (Group SA). Double-blinded randomization was performed by an independent nurse using a computer-generated random sequence. A musculoskeletal radiologist (M. S. H.) with over 20 years of experience performed the diagnostic ultrasound and MRI interpretations. A shoulder specialist (J.-T. H.) with more than 10 years of experience performed the ultrasound-guided injections. A blinded orthopaedic resident and nurse carried out the physical examination and clinical scoring. After the final follow-up, 48 patients (24 in each group) were eligible for analysis

Treatment and Follow-up Protocol Diagnostic ultrasound was first done using a 5- to 12-MHz linear probe (Philips Healthcare, Bothell, WA) to rule out shoulder pathology other than impingement syndrome. Using a 21-gauge spinal needle, a solution of 1mL triamcinolone, 4mL 1% lidocaine, and 7mL 0.9% normal saline was injected under ultrasound guidance using 5- to 13-MHz linear probe (GE Healthcare, Chicago, IL) into either the glenohumeral space through the posterior approach or the subacromial space through the anterolateral approach. Patients were then seen in 3, 7, and 13 weeks after the injection. Oral aceclofenac 100 mg twice daily and omeprazole 20mg once daily were prescribed during follow-up. Stretching exercises in all ranges of motions commenced in the third week. Using a wand, patients were instructed to passively stretch their shoulders to an endpoint where pain is felt and keep that position for at least 30 seconds, five sessions a day, five minutes per session. Rubber band strengthening was added in the seventh week, concentrating on external rotation at the side. Using a rubber band (Thera-band, Hygienic Corp., Akron, OH) tied into a loop, the patients were educated to keep maximum painless external rotation for 30 seconds, five sessions a day, five minutes per session. The tension of the rubber band was decided depending on the patients' ability to keep the painless maximum rotation for thirty seconds.

Clinical Assessment and Data Collection Patient information, including age, sex, duration of symptoms, affected side, and hand dominance, was recorded. The following assessments were performed at baseline and at follow-up visits in weeks 3, 7, and 13: range of motion (ROM) in forward elevation (FE), external rotation at the side (ER), and internal rotation at 90˚ of abduction (IR), pain visual analog scale (pVAS), American Shoulder and Elbow Surgeons (ASES) score, and the Constant-Murley (Constant) score. The ASES score was chosen as it was much verified to best reflect the activities of daily living, while strength was evaluated through the Constant score Improvement in ROM was calculated by subtracting the pre-injection measurements from the measurements at each follow-up visit.

Statistical Analysis A power analysis determined that a sample size of 42 patients (21 per group) would be sufficient to have an 80% statistical power to detect a significant difference in the improvement of the Constant score between pre-injection and 7-week post-injection, with a two-sided α level of 0.05. An effect size of 0.89 was assumed based on the mean difference and standard deviation of improvement in the Constant score between pre-injection and 7-week post-injection in a pilot study of 20 patients.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Double (Participant, Outcomes Assessor)

盲法说明

A final number of 51 patients were enrolled in the trial and randomly assigned to either the glenohumeral ultrasound-guided injection group (Group GH) or the subacromial ultrasound-guided injection group (Group SA). Double-blinded randomization was performed by an independent nurse using a computer-generated random sequence. A musculoskeletal radiologist, blinded to group allocation, performed the diagnostic ultrasound and MRI interpretations. A blinded orthopaedic resident and nurse carried out the physical examination and clinical scoring.

入排标准

年龄范围
20 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Diagnosed with shoulder impingement syndrome with mild stiffness.
  • Impingement syndrome diagnosed based
  • Positive Hawkin's sign and
  • Rotator cuff with intact continuity but tendinosis in MRI or US
  • Possible subacromial enthesophyte
  • Mild stiffness was defined as a degree of stiffness that permits activities of daily activity but still often causes endpoint ROM pain
  • Meeting two or more of the following ROM both active & passive
  • Abduction between 110˚ and 150˚
  • Forward elevation between 120˚ and 140˚
  • External rotation at the side between 30˚ and 50˚
  • Internal rotation at 90˚ of abduction between 30˚ and 50˚.

排除标准

  • Refused to undergo ultrasound-guided injection
  • Diagnosed with a rotator cuff tear, calcific tendinosis, or biceps pathology
  • History of operation, fracture, or nerve injury of the shoulder
  • Received treatment apart from the protocol during the study

结局指标

主要结局

Range of motion (ROM)

时间窗: Change from the baseline at 13 weeks

ROM in degrees, forward elevation (0-150), external rotation (0-90), and internal rotation (0-90)

Visual analog scale (VAS) for pain

时间窗: Change from the baseline at 13 weeks

Patient-reported 0-10 scale of pain, 0: no pain, 10: very severe pain

American Shoulder and Elbow Surgeons (ASES) shoulder score

时间窗: Change from the baseline at 13 weeks

Patient-reported shoulder satisfaction score, 0-100, higher scores mean a better outcome.

Constant score

时间窗: Change from the baseline at 13 weeks

Patient-reported and healthcare provider-assessed shoulder satisfaction score, 0-100, higher scores mean a better outcome.

次要结局

未报告次要终点

研究者

发起方
Chuncheon Sacred Heart Hospital
申办方类型
Other
责任方
Principal Investigator
主要研究者

Jung-Taek Hwang

Professor

Chuncheon Sacred Heart Hospital

研究点 (2)

Loading locations...

相似试验