跳至主要内容
临床试验/NCT06056388
NCT06056388尚未招募不适用

Is the Accuracy of Immediate Implant Placement Using Dynamic Navigation Affected by Fixture Thread Depth?: A Randomized Controlled Trial

Shanghai Ninth People's Hospital Affiliated to Shanghai Jiao Tong University0 个研究点目标入组 30 人开始时间: 2023年12月31日最近更新:
适应症

试验速览

阶段
不适用
状态
尚未招募
发起方
入组人数
30
主要终点
Placement accuracy measured as global platform deviation in millimeters and assessed by DCarer or coDiagnostiX

研究概览

简要总结

The goal of this clinical trial is to compare the placement accuracy in immediately placed implants using dynamic navigation between deep-threaded and regular-threaded implants in partially edentulous patients. The main question it aims to answer is: is there a difference in implant placement accuracy between deep-threaded and regular-threaded implants using dynamic navigation? Participants will receive implants placed immediately under dynamic guidance. Researchers will compare type of implant thread (Straumann BLT versus Straumann BLX) to see if there are significant differences in placement accuracy.

详细描述

The initial visit will comprise a thorough clinical examination and panoramic radiograph acquisition. Hopeless teeth resulting from trauma, periapical abscess, and periodontitis will be evaluated to see if extraction indications are met. When extraction indications were met, patients will be evaluated for suitable bone height for immediate implant placement. When bone height was suitable, patients will be asked to take a preoperative CBCT scan.

After tooth condition and bone volume evaluations, patients with adequate bone volume for immediate implant placement will be enrolled and randomly assigned to one of two groups: deep-threaded or regular-threaded.

The following implant placement accuracy parameters will be recorded using postoperative intraoral scanning superimposition: Global platform deviation (measured in millimeters), lateral platform deviation (measured in millimeters), global apex deviation (measured in millimeters), apex depth deviations (measured in millimeters), and angular deviation (measured in degrees). Primary implant stability will be measured immediately after implant insertion and measured in both insertion torque value and implant stability quotient. Radiographic bone-implant contact will be measured with a 3D implant model reconstruction method using coDiagnostiX and the contact area will be calculated using 3-matic Research as previously reported. Marginal bone loss will be measured using ImageJ with periapical radiographs taken 3 months and 1-year post-op. Implant survival will be monitored starting from the final prosthesis delivery onwards. Complications (biological, technical, and implant loss) will be recorded accordingly. Patient satisfaction will be documented with a Mandarin Chinese version of the Short Form Patient Satisfaction Questionnaire (PSQ-18) upon final prosthesis delivery.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Hopeless teeth that require extraction
  • No systemic diseases
  • Smoking (<10 cigarettes/day)
  • Full-mouth bleeding and full-mouth plaque index lower than or equal to 25%
  • Fresh extraction sockets with at least 3 fully intact socket walls
  • At least 4 mm of bone beyond the root apex
  • Meets one of the following:
  • Single immediate placement site in the maxillary esthetic zone [15-25 (FDI classification)].
  • Two or more nonconsecutive immediate placement sites in the maxillary esthetic zone [15-25 (FDI classification)].
  • Two or more consecutive immediate placement sites in the maxillary esthetic zone [15-25 (FDI classification)].

排除标准

  • General medical (American Society of Anesthesiologists, ASA, class III or IV) and/or psychiatric contraindications
  • Pregnancy or nursing
  • Any interfering medication such as steroid therapy or bisphosphonate therapy
  • Alcohol or drug abuse
  • Heavy smoking (>10 cigarettes/day)
  • Radiation therapy to head or neck region within 5 years
  • Untreated periodontitis
  • Refuse to participate in this trial

结局指标

主要结局

Placement accuracy measured as global platform deviation in millimeters and assessed by DCarer or coDiagnostiX

时间窗: Postoperative (Day 1-5)

Sufficiently described in the Title

Placement accuracy measured as global apex deviation in millimeters and assessed by DCarer or coDiagnostiX

时间窗: Postoperative (Day 1-5)

Sufficiently described in the Title

Placement accuracy measured as apex depth deviations in millimeters and assessed by DCarer or coDiagnostiX

时间窗: Postoperative (Day 1-5)

Sufficiently described in the Title

Placement accuracy measured as angular deviation in degrees and assessed by DCarer or coDiagnostiX

时间窗: Postoperative (Day 1-5)

Sufficiently described in the Title

Placement accuracy measured as lateral platform deviation in millimeters and assessed by DCarer or coDiagnostiX

时间窗: Postoperative (Day 1-5)

Sufficiently described in the Title

次要结局

  • Amount of marginal bone loss measured in millimeters using periapical radiographs(Postoperative (1 year))
  • Rate of implant survival measured in percentage(Postoperative (4 months & 1 year))
  • Level of patient satisfaction measured using the Short Form Patient Satisfaction Questionnaire(Postoperative (4 months & 1 year))
  • Level of primary implant stability measured in insertion torque (ITV) using a Torq Control(Intraoperative (Day 0))
  • Amount of radiographic bone-implant contact measured in millimeters using 3-matic Research(Postoperative (Day 1-5))
  • Level of primary implant stability measured in implant stability quotient (ISQ) using an Osstell Beacon(Intraoperative (Day 0))
  • Number of participants with biological or technical complications(Postoperative (Up to 1 year))

研究者

发起方
Shanghai Ninth People's Hospital Affiliated to Shanghai Jiao Tong University
申办方类型
Other
责任方
Sponsor

相似试验

Effect of Fixture Thread Depth on Accuracy of... | 临床试验