MedPath

Effect of Different Types of Aerobic Training on Peak VO2 and Ejection Fraction for Diastolic Heart Failure Patients; a Comparative Randomized Control Trial

Not Applicable
Completed
Conditions
Effect of Different Types of Aerobic Training on Diastolic Heart Failure Patients
Interventions
Other: aerobic exercise for lower limb
Other: aerobic exercise for upper limb
Registration Number
NCT05637125
Lead Sponsor
Beni-Suef University
Brief Summary

Background: Heart failure is described by a lack of confirmed efficient therapies and exercise intolerance. Physical activity is related to a lower risk of adverse cardiovascular consequences, involving heart failure. The purpose of the study: determine the effect of different types of aerobic training on peak VO2 and ejection fraction in diastolic heart failure patients. Subject and methods: Forty eligible male patients with diastolic heart failure, aged between 50 - 60 years old, participated in this study. They were selected from an outpatient clinic of general Zagazig hospital and were assigned into 2 equal groups in numbers. The first group (A) received aerobic exercise for the upper limb in form of arm ergometer exercises, while the second group (B) received aerobic exercise for the lower limb in form of cycling. Training duration for both groups was 3 sessions/week for 12 weeks. Peak VO2, and ejection fraction of both groups were measured and compared pre and post-treatment. Results: There was no significant difference in the ejection fraction between groups post-treatment. There was a significant increase in the peak VO2 of group B compared with that of group A post-treatment. Conclusion: there is no effect of different types of aerobic training on ejection fraction and peak VO2 for diastolic heart failure patients, but lower limb exercise is more effective than upper limb exercise in improvement of peak VO2 for diastolic heart failure patients.

Detailed Description

Ejection fraction and peak VO2 of both groups were measured pre exercise program and after 12 weeks at the end of the study exercise program.

* Vivid S5 cardiovascular ultrasound system (BT308), made in china, was used to measure ejection fraction.

* Oxycon pro (ER900, Germany) cardiopulmonary exercise test unit was used to measure Peak Vo2

Treatment procedure:

Group A received aerobic exercise for upper limb in the form of arm ergometer 3 session/week for 12 weeks. Patient started with warming up for 5 minutes in form of stretching. Patients used arm ergometer without resistance for upper limb aerobic exercise for 20 minutes and instructed to take rest if they feel tired or fatigue. The intensity was according to rate of perceive exertion, after 20 minutes, patients were asked to cool down for 5 minutes in the form of stretching at the end of an exercise session.

Group B received aerobic exercise for lower limb in the form of cycling 3session/week for 12 weeks. Patient started with warming up for 5 minutes. Patients used bicycle for lower limb aerobic exercise for 20 minutes and instructed to take rest if they feel tired or fatigue. The intensity was according to rate of perceive exertion. After 20 minutes, patients were asked to cool down for 5 minutes in the form of stretching at the end of an exercise session.

Recruitment & Eligibility

Status
COMPLETED
Sex
Male
Target Recruitment
40
Inclusion Criteria
  • male gender
  • under complete medical supervision
  • left ventricular end diastolic dimension >5.5cm
  • ejection fraction <50%.
Exclusion Criteria
  • Orthopedic problems
  • Mental disorders
  • Metabolic disorders (D.M)
  • Current treatment for cancer or active infection.

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Group Baerobic exercise for lower limbreceived aerobic exercise for lower limb in the form of cycling 3session/week for 12 weeks.
Group Aaerobic exercise for upper limbGroup A received aerobic exercise for upper limb in the form of arm ergometer 3 session/week for 12 weeks.
Primary Outcome Measures
NameTimeMethod
Ejection fraction12 weeks

Vivid S5 cardiovascular ultrasound system (BT308), made in china, was used to measure ejection fraction.

peak VO212 weeks

Oxycon pro (ER900, Germany) cardiopulmonary exercise test unit was used to measure Peak Vo2

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Beni-Suef University

🇪🇬

Banī Suwayf, Sharq, Egypt

© Copyright 2025. All Rights Reserved by MedPath